Omron H2C Manual page 3

Motor timer h2c series
Hide thumbs Also See for H2C:
Table of Contents

Advertisement

■ Characteristics
Accuracy of operating time
Setting error
Reset time
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
Motor life expectancy
Approved standards
EMC (except for H2C-F@ models)
Case color
Degree of protection
Weight
■ Life-test Curve
300
200
100
250 VAC cosφ = 1
50
24 VDC cosφ = 1
40
30
20
10
5
1
2
3
4
5
6
Load current (A)
± 0.5% FS max. á± 1% max. at 0.2 to 6 s for the time range code B or at 0.5 to 12 s for the time range
code C)
± 2% FS max.
0.5 s max.
± 1% FS max.
± 2% FS max.
100 M Ω min. (at 500 VDC)
2,500 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts)
2,000 VAC, 50/60 Hz for 1 min (between contact and control circuit and between contacts of different
polarities)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Destruction:
10 to 55 Hz with 0.375-mm single amplitude for 1 h each in three directions
Malfunction:
10 to 55 Hz with 0.25-mm single amplitude for 10 min each in three directions
2
Destruction:
1,000 m/s
2
Malfunction:
150 m/s
–10 ° C to 50 ° C
Operating:
–25 ° C to 65 ° C
Storage:
Operating:
45% to 85%
Mechanical:
10,000,000 operations min. (under no load at 1,800 operations/h)
Electrical:
500,000 operations min. (3 A at 250 VAC, resistive load at 1,800 operations/h)
See Life-test Curve for other details.
20,000 h
UL917, CSA C22.2 No.14.
Conforms to EN61812-1 and IEC60664-1 4 kV/1 (except for H2C-F@ models).
Output category according to EN60947-5-1 (except for H2C-F@ models).
(EMI)
EN61812-1
Emission Enclosure:
EN55011 Group 1 class A
Emission AC Mains:
EN55011 Group 1 class A
(EMS)
EN61812-1
Immunity ESD:
IEC61000-4-2:
Immunity RF-interference from AM Radio Waves: IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity Burst:
IEC61000-4-4:
Immunity Surge:
IEC61000-4-5:
Light gray (Munsell 5Y7/1)
IP40 (panel surface)
H2C series:
approx. 180 g
H2C-F series: approx. 270 g
300
200
100
50
40
30
250 VAC cosφ = 0.4
20
24 VDC L/R = 7 msec
10
5
1
2
3
4
5
6
6 kV contact discharge (level 3)
8 kV air discharge (level 3)
2 kV power-line (level 3)
2 kV I/O signal-line (level 4)
1 kV line to line (level 3)
2 kV line to ground (level 3)
Load current (A)
H2C
Motor Timer
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H2c-8H2c-sH2c-fH2c-8rH2c-rH2c-sr ... Show all

Table of Contents