Motor Timer
Miniature, High-performance Motor
Timer
Employs high-reliability bifurcated contacts for
output.
Moving pointer provided in all types for confirmation
of elapsed time.
Employs time-out and power ON indicators for all
types.
Wide variety of timing ranges from 5 s to 24 hrs.
Ordering Information
Operation/resetting system
p
g y
Time-limit operation/
p
self-resetting
lf
tti
Note: 1. Specify both the model number and supply voltage when ordering.
2. Surface mounting models can be used as a flush mounting type by attaching an exclusive adapter (Y92F-40) to the timer.
Specifications
Time Ranges
Rated time
5 s
10 s
30 s
60 s
3 min
6 min
12 min
30 min
60 min
3 hrs
6 hrs
12 hrs
24 hrs
Ratings
Rated supply voltage
Operating voltage range
Power consumption
Control outputs
Note: The front panel of the timer is color-coded to identify the following supply voltage classifications:
100, 110 V:
Blue
200, 220 V:
Red
Other classes: Black
Internal connection
Parallel motor and
SPDT
clutch connection
l t h
ti
Time setting range
50 Hz
0.2 to 6 s
0.5 to 12 s
1 to 36 s
2 to 72 s
1/6 to 3 1/2 min
1/4 to 7 1/6 min
1/2 to 14 min
1 to 36 min
2 to 72 min
1/6 to 3 1/2 hrs
1/4 to 7 hrs
1/2 to 14 hrs
1 to 28 hrs
100, 110, 200, or 220 VAC (50 Hz), 100/110, 200/220 VAC (60 Hz)
85% to 110% of rated supply voltage
Approx. 3 VA
Standard type: 2 A at 250 VAC, resistive load (cosφ = 1)
Time-limit
Instantaneous
contact
t
t
contact
t
---
SPST-NO
60 Hz
0.2 to 5 s
0.5 to 10 s
1 to 30 s
2 to 60 s
1/6 to 3 min
1/4 to 6 min
1/2 to 12 min
1 to 30 min
2 to 60 min
1/6 to 3 hrs
1/4 to 6 hrs
1/2 to 12 hrs
1 to 24 hrs
H2A
Mounting
t
Surface mounting
(see note 2)
H2A
H2A-H
Time division
0.2 s
0.5 s
1.0 s
2.0 s
10.0 s
15.0 s
30.0 s
1.0 min
2.0 min
10.0 min
15.0 min
30.0 min
1.0 hrs
1

Advertisement

loading

Summary of Contents for Omron H2A

  • Page 1 SPST-NO H2A-H Note: 1. Specify both the model number and supply voltage when ordering. 2. Surface mounting models can be used as a flush mounting type by attaching an exclusive adapter (Y92F-40) to the timer. Specifications Time Ranges Rated time...
  • Page 2 100 MΩ min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts, between contact and control circuit and between) contacts of different polarities) 1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts) Vibration resistance Destruction: 16.7 Hz with 4-mm double amplitude...
  • Page 3 Dimensions Note: All units are in millimeters unless otherwise indicated. H2A/H2A-H Note: F-shaped hook (PHC-1) for PF085A and L-shaped hook (PHc-4) for PL08 are supplied with the timer. H2A(-H) with Adapter Panel Cutouts Y92F-40 adapter for Panel flush mounting (See note) Note: Back connecting socket US08 and Y-shaped hook PHC-3 are supplied with the timers.
  • Page 4 40°C, be sure to reset the timers immediately after the set time has elapsed. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. Cat. No. L04-E1-8...