■ Characteristics
Item
Operate time
Release time
Output ON voltage drop
Leakage current
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Certified standards
Weight
Engineering Data
Load Current vs. Ambient Temperature
G3NE-205T(L)(-2)-US
Without heat sink
Ambient temperature ( C)
One Cycle Surge Current: Non-repetitive
Note: Keep the inrush current to half the rated value if it occurs repetitively.
G3NE-205T(L)(-2)-US
Energized time (ms)
G3NE-2@@T(-2)-US
1/2 of load power source cycle + 1 ms max.
1/2 of load power source cycle + 1 ms max.
1.6 V (RMS) max.
2 mA max. (at 100 VAC)
5 mA max. (at 200 VAC)
100 M min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude
2
Destruction: 1,000 m/s
Operating: –30 C to 80 C (with no icing or condensation)
Storage:
–30 C to 100 C (with no icing or condensation)
Operating: 45% to 85%
UL508 File No.E64562/CSA C22.2 (No.0, No.14) File No. LR35535
TÜV R9051064 (VDE0435) (EN60950)
Approx. 37 g
G3NE-210T(L)(-2)-US
With standard heat sink (Y92B-N50)
or aluminum plate measuring 100 mm
x 100 mm x t2 mm (W x H x D)
Without heat sink
Ambient temperature ( C)
G3NE-210T(L)(-2)-US
Energized time (ms)
G3NE-2@@TL(-2)-US
1 ms max.
G3NE-220T(L)(-2)-US
With standard heat sink (Y92B-N100) or
aluminum plate measuring 300 mm x
300 mm x t3 mm (W x H x D)
Without heat sink
Ambient temperature ( C)
G3NE-220T(L)(-2)-US
Energized time (ms)
G3NE