Nice MLAE 21 Instructions And Warnings For Installation

Nice MLAE 21 Instructions And Warnings For Installation

I/o expansion board

Advertisement

Quick Links

MLAE
MLAE 21
MLAE 22
MLAE 44
I/O expansion board
EN
Instructions and warnings for installation
-

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MLAE 21 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Nice MLAE 21

  • Page 1 MLAE MLAE 21 MLAE 22 MLAE 44 I/O expansion board Instructions and warnings for installation...
  • Page 2: Table Of Contents

    According to the most recent European legislation, the 5.2.1 MLAE 21 “Gate” and “Door” ......6 implementation of an automation system must comply 5.2.2 MLAE 22 “Gate”...
  • Page 3: Product Description

    PRODUCT DESCRIPTION PRODUCT DESCRIPTION MLAE21, MLAE22 and MLAE24 are expansion boards for modular control units. The expansion board makes available additional inputs and outputs. Each additional input and/or output can be personalised as if it were a physical input and/or output of the control unit. Whenever an expansion board is added or removed, it may be necessary to run the “device acquisition”...
  • Page 4: Installation

    EXTERNAL CONNECTIONS INSTALLATION MLAE 44 is supplied wired. Input “IN6” is configured by default as “Photo” or “Open in emergency mode”. These are two safety mechanisms that are INSTALLATION normally closed under normal conditions. PRE-INSTALLATION CHECKS The installation must be carried out by qualified person- nel in compliance with the current legislation, standards and regulations, and with the instructions provided in this manual...
  • Page 5: Testing And Commissioning

    “temporary” conditions met, in particular all the requirements of the EN 12445 standard, which defines the test methods for checking For all the above-mentioned documentation, Nice – gate automations through its technical assistance service – provides the following: pre-completed forms, instruction manuals and...
  • Page 6: Settings

    Partial open 1 One-way traffic light Red traffic light PhotoTest emergency mode light TYPICAL CONNECTIONS 5 2 1 MLAE 21 “GATE” AND “DOOR” 5 2 2 MLAE 22 “GATE” AND “DOOR” Table 5 Table 6 DEFAULT VALUES DEFAULT VALUES GATE...
  • Page 7: Mlae 44 "Gate" And "Door

    5 2 3 MLAE 44 “GATE” AND “DOOR” PRODUCT DISPOSAL PRODUCT DISPOSAL As in installation, also at the end of product lifetime, the disassembly and scrapping operations must be performed by qualified personnel. This product is made of various types of materials, some of which can be recycled while others must be scrapped.
  • Page 8 Nice S.p.A. Via Callalta, 1 31046 Oderzo TV (Italy) www.niceforyou.com info@niceforyou.com...

This manual is also suitable for:

Mlae 22Mlae 44

Table of Contents