Nice Moon MC824H Instructions And Warnings For Installation And Use

Hide thumbs Also See for Moon MC824H:

Advertisement

Moon
Control unit
MC824H
EN -
Instructions and warnings for installation and use
IT -
Istruzioni ed avvertenze per l'installazione e l'uso
FR -
Instructions et avertissements pour l'installation et l'utilisation
ES -
Instrucciones y advertencias para la instalación y el uso
DE -
Installierungs-und Gebrauchsanleitungen und Hinweise
PL -
Instrukcje i ostrzeżenia do instalacji i użytkowania
NL -
Aanwijzingen en aanbevelingen voor installatie en gebruik

Advertisement

Table of Contents
loading

Summary of Contents for Nice Moon MC824H

  • Page 1 Moon Control unit MC824H EN - Instructions and warnings for installation and use IT - Istruzioni ed avvertenze per l’installazione e l’uso FR - Instructions et avertissements pour l’installation et l’utilisation ES - Instrucciones y advertencias para la instalación y el uso DE - Installierungs-und Gebrauchsanleitungen und Hinweise PL -...
  • Page 3: Table Of Contents

    Read all parts of the manual carefully before starting work. If in doubt, interrupt installation and contact the Nice Service Centre for clarifications. GENERAL SAFETY WARNINGS AND PRECAUTIONS....1 •...
  • Page 4: Product Application Limits

    To mount the control unit, proceed as shown in fig. 3: 01. Open the control unit box by undoing the relevant screws (fig. 3-A); Fig. 2 shows an example of an automation system set up with Nice components: 02. Prepare the electrical cable routing holes (fig. 3-B);...
  • Page 5: Connection Of Other Devices To Mc824H

    IMPORTANT! – Connections must be made exclusively by qualified per- 3.6.1 - Selecting the motor type and learning procedure in automatic sonnel. mode: 01. Press and hold down “Set” and keys at the same time. 3.2 - Connection of other devices to MC824H 02.
  • Page 6: Checking Movement Of Gate Leafs

    01. Press the “Open” key. Check for the correct leaf opening offset and check For all the above-mentioned documentation, Nice provides instruction man- that the opening manoeuvre includes the acceleration, constant speed uals, guides and pre-filled forms through its technical support service.
  • Page 7: Level One Programming (On-Off Functions)

    5.1 - Level one programming (ON-OFF functions) IMPORTANT – In the programming procedure, the maximum time interval that can elapse between activation of one key and the next is 10 seconds. When All level 1 functions are set by default to “OFF” and may be modified at any this time elapses, the procedure terminates automatically, memorising the time.
  • Page 8 TABLE 8 - Second level functions Input LED Parameter Value Description (level) Pause time 5 seconds Sets the pause time, namely the time which lapses before automatic clo- 15 seconds sure. This will only take effect if closing 30 seconds is active.
  • Page 9: Special Functions

    List of Manoeuvre 1 result (most recent) The type of fault that has occurred in faults the last 8 manoeuvres can be establi- Manoeuvre 2 result shed Manoeuvre 3 result See TABLE 12 – Fault log. Manoeuvre 4 result Manoeuvre 5 result Manoeuvre 6 result Manoeuvre 7 result Manoeuvre 8 result...
  • Page 10: Further Details

    TABLE 11 - Signals given by LEDs on control unit (fig. 7) Problem Solution BLUEBUS Always off Fault Check that the control unit is powered. Check that the fuses have not blown: if they have, check the cause of the fault and replace with others with the same value Always on Serious fault...
  • Page 11: Connecting Oview Programming Unit

    Command Description following the relevant warnings) and can remain connected to the control unit during normal operation of the automation. In this case a specific “user” menu Close and block It causes a closure manoeuvre, after which the automation enables commands to be sent directly to the control unit. It is also possible to automation is blocked;...
  • Page 12: Technical Characteristics Of The Product

    Note - The contents of this declaration correspond to declarations in the last revision of the official document deposited at the registered offices of Nice Spa available before this manual was printed.
  • Page 13: Appendix

    Appendix • Instructions and warnings for the user • Images Appendice • Istruzioni ed avvertenze destinate all’utilizzatore • Immagini Appendice • Instructions et recommandations destinées à l’utilisateur • Images Apéndice • Instrucciones y advertencias destinadas al usuario • Imágenes Anhang •...
  • Page 14: Instructions And Warnings For The User

    Instructions and warnings for the user Before using the automation for the first time, ask the installer to explain • Disposal: At the end of the automation’s lifetime, ensure that it is dis- the origin of residual risks and devote a few minutes to reading this user posed by qualified personnel and that the materials are recycled or scrapped according to current local standards.
  • Page 15 232 mm 122 mm...
  • Page 16 24V 4W NC NO NO NC P.P. STOP – 24 Vcc FLASH S.C.A. BLUEBUS P.P. STOP OPEN CLOSE L1 L2 L3 L4 L5 L7 L8...