Precautions For Correct Use - Omron E3X-SD Series Brochure

Simple fiber amplifiers
Hide thumbs Also See for E3X-SD Series:
Table of Contents

Advertisement

Precautions for Correct Use

Do not use the product in atmospheres or environments that
exceed product ratings.
Amplifier Units
● Designing
Communications Hole
The hole on the side of the Amplifier Unit is a communications
hole for preventing mutual interference when Amplifier Units
are mounted side-by-side. The E3X-MC11 Mobile Console
(order separately) cannot be used.
If an excessive amount of light is received via the Sensor, the
mutual interference prevention function may not work. In this
case, make the appropriate adjustments using the sensitivity
adjuster.
The mutual interference prevention function will not operate
when the E3X-SD/NA is used side-by-side with E3X-DA-N
models.
● Mounting
DIN Track Mounting/Removal
Mounting Amplifier Units
1. Mount the Amplifier Units one at a time onto the DIN track.
2. Slide the Amplifier Units together, line up the clips, and
press the Amplifier Units together until they click into place.
Clip
Removing Amplifier Units
Slide Amplifier Units away from each other, and remove from
the DIN track one at a time. (Do not attempt to remove
Amplifier Units from the DIN track without separating them
first.)
Note 1. The specifications for ambient temperature will vary according to the
number of Amplifier Units used together. For details, refer to Ratings
and Specifications.
2. Always turn OFF the power supply before mounting or removing
Amplifier Units.
Click into
place
Fiber Connection and Disconnection
The E3X Amplifier Unit has a lock lever. Connect or
disconnect the fibers to or from the E3X Amplifier Unit using
the following procedures:
1. Connection
Open the Protective Cover, insert the fibers according to the
fiber insertion marks on the side of the Amplifier Unit, and
lower the lock lever.
Lock lever
Fiber insertion mark
Fiber
2. Disconnection
Remove the Protective Cover and raise the lock lever to pull
out the fiber.
Unlocked
Locked
Note:To maintain the fiber properties, confirm that the lock is
released before removing the fiber.
3. Precautions for Fiber Connection/Disconnection
Be sure to lock or unlock the lock lever within an ambient
temperature range between −10°C and 40°C.
● Operating Environment
Ambient Conditions
If dust or dirt adhere to the hole for optical communications, it
may prevent normal communications. Be sure to remove any
dust or dirt before using the Units.
● Other
Protective Cover
Be sure to mount the Protective Cover before use.
E3X-SD/-NA
Insertion position
10.7 mm
Protective Cover
13