Amplifier Unit Connectors
Installation
Connector installation
1. Insert the Master or Slave Connector into the amplifier unit
until it clicks into place.
2. Link amplifier units to each other after the master and slave
Connectors have been inserted.
3. Apply the supplied seal to the non-connecting surface of the
master/slave connector.
Sticker
Note: Apply seal to the grooved side.
Removing Connectors
1. Slide the slave amplifier unit (s) on which the connector
must be removed from the rest of the group.
2. After the amplifier unit (s) has been separated, press down
the lever on the connector and remove it. (Do not attempt
to remove connectors without separating them from other
amplifier units first.)
E3X-DA-N
Insert
Sticker
Press down
Lever
Remove
Mounting End Plate (PFP-M)
Depending on the installation, an amplifier unit may move dur-
ing operation. In this case, use an end plate.
Before installing an end plate, remove the clip from the master
amplifier unit using a nipper or similar tool.
Clip
The sensor bottom is also equipped with a clip removing
mechanism.
1. Insert the clip to be removed into the slit underneath the clip
on another amplifier unit.
2. Remove the clip by rotating the amplifier unit.
Rotate
When fitting the Mobile Console, set the end plate in the guide
as shown in the following figure.
End Plate
Tensile stress for connectors (including cables)
E3X-CN11, E3X-CN21, E3X-CN22: 30 N max.
E3X-CN12: 12N max.