QUICK START GUIDE
HP290 MONOBLOC HEAT PUMP SYSTEM
for Installation
& Maintenance
READ BEFORE COMMISSIONING
When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by Ideal Heating.
For the very latest copy of literature for specification and maintenance practices visit our website idealheating.com
where you can download the relevant information in PDF format.
April 2024
UIN 241625 A01
SCAN
SCAN
for
Schematics
Guide
Guide
IMPORTANT!
SCAN
SCAN
for Halo Lite
for Hybrid
RF Installation
Instructions
Manual
Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HP290 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ideal Heating HP290

  • Page 1 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by Ideal Heating.
  • Page 2 NOTE TO INSTALLER: COMPLETE THE BENCHMARK COMMISSIONING CHECKLIST AT THE REAR OF THIS BOOK AND LEAVE THESE INSTRUCTIONS WITH APPLIANCE Ideal Heating reserve the right to vary specification without notice...
  • Page 3: Table Of Contents

    CONTENTS 1.1 HP290 Control Box/Controller Configuration ..........4 1.1.1 HP290 Cylinder or HP290 Control Box ........... 4 1.1.2 HP290 Controller ................5 1.2 HP290 System Parameter Update using USB ..........6 1.3 Enabling CH operation .................. 7 1.3.1 Temperature Curve ................8 1.4 Enabling CH Zone 2 (if applicable) ................9 1.5 Operating Status ..................10...
  • Page 4: Hp290 Control Box/Controller Configuration

    ⓘ IMPORTANT: Before the Ideal HP290 Monobloc is powered up for the first time, you must configure the unit to use the correct type of controller. Refer to the INSTALLATION & MAINTENANCE MANUAL for further details. 1.1.1 HP290 Cylinder or HP290 Control Box...
  • Page 5: Hp290 Controller

    Figure 2. HP290 Monobloc (Access to Outdoor Control PCB) 1.1.2 HP290 Controller Set the HP290 Monobloc DIP switch as follows: 1. Remove the HP290 Monobloc top panels. Refer to the HP290 Installation & Maintenance manual 4.1.7 Accessing the Casing. 2. Gain access to the HP290 Monobloc Outdoor Control PCB.
  • Page 6: Hp290 System Parameter Update Using Usb

    Section 1 - General 1.2 HP290 SYSTEM PARAMETER UP- DATE USING USB ᘐ 3. Power up the indoor unit and then power up the outdoor WARNING: All electrical work is to be undertaken unit. Wait until the Control display shows the USB by a competent electrician.
  • Page 7: Enabling Ch Operation

    Section 1 - General 1.3 ENABLING CH OPERATION Enable CH operation as follows: Zone1 From the Home Screen (above), press to move to the Menu page (below). Mode Press twice to highlight the Weather temp. settings option, then press O and the below will be shown. Weather temp.
  • Page 8: Temperature Curve

    2- T1S 65.0 3- T1S 60.0 55.0 4- T1S 50.0 5- T1S 45.0 6- T1S 40.0 35.0 7- T1S 30.0 8- T1S 25.0 20.0 - 20 - 10 ≥ 20 Ambient temp. Figure 6. HP290 Standard Curve Graph Quick Start Guide...
  • Page 9: Enabling Ch Zone 2 (If Applicable)

    Section 1 - General 1.4 ENABLING CH ZONE 2 (if applicable) Enable CH zones as follows: For serviceman Service call Setting is enabled. Quit For serviceman mode? Restore factory settings Test run Zone1 Special function Repeatedly press to exit the For serviceman menu. Press and hold together.
  • Page 10: Operating Status

    Section 1 - General 1.5 OPERATING STATUS Use the Operating Status display to activate Zones and DHW. Holiday Mode Compressor On Immersion Heater On Switching Time Date & Time Zone 1 Target Temperature Operating Mode In Legionella Protection Mode In Daily Timed Operation Backup Boiler On Low Tari Operation On Outdoor Unit Pump On...
  • Page 11 Notes Quick Start Guide...
  • Page 12 At Ideal Heating we take our environmental impact seriously, therefore when installing any Ideal Heating product please make sure to dispose of any previous appliance in an environmentally conscious manner. Households can contact their local authority to find out how.