Type
Model
Mode switch
PNP
E3S-AT31
Light ON
E3S-AT36
E3S-AT81
E3S-AT86
E3S-AR31
E3S-AR36
E3S-AR81
E3S-AR86
E3S-AD33
E3S-AD83
E3S-AD38
E3S-AD88
E3S-AD31
E3S-AD36
E3S-AD81
E3S-AD86
Dark ON
E3S AD32
E3S-AD37
E3S-AD82
E3S AD87
E3S-AT41
Light ON
E3S-AT91
E3S-AD43
E3S-AD93
E3S-AD41
E3S-AD91
E3S-AD42
E3S-AD92
Dark ON
E3S-AR41
Light ON
E3S-AR91
Dark ON
A-238
Output transistor
ON when light is re-
Emitter
ceived
E3S-AT31/AT36/
AT81/AT86
Light
(Red)
(Green)
ON when light is
Connector Type
not received
Emitter
ON when light is re-
Emitter E3S-AT41/AT91
ceived
Emission (Red)
Main
circuit
ON when light is
not received
Light
(Red)
ON when light is re-
ceived
ON when light is
not received
Light
(Red)
Output circuit
Emission (Red)
Main
circuit
Stability
Z
D
Main
circuit
Reflective/Receiver
+ V
0 V
Brown
10 to 30 VDC
External-diagnostic
input
Pink
Blue
0 V
Stability
Z
D
50 mA max.
Main
Z
D
(Green)
circuit
100 mA max.
4.4K
Stability
Z
D
50 mA
max.
Main
Z
D
circuit
(Green)
100 mA max.
Standard Photoelectric Sensors
Brown
10 to
30 VDC
Blue
Brown
Control
output
Black
10 to
100 mA
30 VDC
max.
Load
Blue
(relay)
Z
: V
= 39 V
D
Z
+ V
Output
Load (relay)
Pin No. 2 is open.
0 V
External
ON
diagnostic input
OFF
ON
LED for emitter
OFF
ON
Indicator (red)
OFF
Brown
Self-diagnostic
output
Orange
10 to 30 VDC
Control
output
Load
Black
(relay)
Load
(relay)
Blue
Z
: V
= 39 V
D
Z
Brown
Pink
External-diag-
nostic input
Self-diagnos-
tic output
Orange
10 to 30 VDC
Control
output
Load
Black
(relay)
Load
(relay)
Blue
Z
: V
= 39 V
D
Z

Hide quick links: