Page 1
RS422/RS485 Modbus Gateway SMG-5521 User Manual Version 1.0 Sollae Systems https://www.ezTCP.com...
Page 2
SMG-5521 User Manual Ver. 1.0 This symbol, found on your product or on its packaging, indicates that this product should not be treated as household waste when you wish to dispose of it. Instead, it should be handed over to an applicable collection point for the recycling of electrical and electronic equipment.
SMG-5521 User Manual Ver. 1.0 Modbus Overview 1.1 Modbus Modbus is a serial communications protocol originally published by Modicon (now Schneider Electric) in 1979 for use with its programmable logic controller (PLCs). As a matter of fact, Modbus has become a standard communication protocol.
SMG-5521 User Manual Ver. 1.0 1.2 Modbus Gateway Figure 1-1 Modbus Gateway The communication range of the Modbus RTU/ASCII device is restricted. However, the Modbus Gateway extends this range by collecting data from the Modbus device and transmitting it securely to the Sollae Cloud via the Internet. Within the Sollae Cloud platform, the data is efficiently managed, stored, and visualized in diverse ways.
Product Overview 2.1 Product Overview The SMG-5521 serves as an industrial Modbus Gateway, connecting your Modbus RTU/ASCII devices/sensors to the Sollae Cloud. Through the Sollae Cloud's web interface, you gain the ability to both retrieve data from and control your Modbus RTU/ASCII devices/sensors.
Page 8
SMG-5521 User Manual Ver. 1.0 1:1 or Cross-over Cable Auto Sense Software Functions Protocols IPv4/IPv6 Dual Stack TCP/UDP, ICMP, DHCP, mDNS, MQTT Modbus/RTU, Modbus/ASCII, SSL/TLS Indicators PWR, LINK, RUN, MTX, MRX, STX, SRX, STS Management spFinder Configuration and Monitoring Tool...
SMG-5521 User Manual Ver. 1.0 2.4 Interface Figure 2-1 Interface 2.4.1 Power SMG-5521 requires DC5V power supply whose specification is as follows: Figure 2-2 Power - 8 - https://www.ezTCP.com...
SMG-5521 User Manual Ver. 1.0 2.4.2 Ethernet SMG-5521 provides 10/100Mbps Ethernet. The pin assignment is as follows: Figure 2-3 Ethernet 2.4.3 Serial Port SMG-5521 has a 3.5mm pitch 6-pole terminal block for connecting serial devices. Figure 2-4 Serial Port ⚫ Port Specification Parameter Value...
Page 11
SMG-5521 User Manual Ver. 1.0 ⚫ RS485 Signal Lines Label Name Description Level Wiring TRX + Data + RS485 In/Out Required TRX - Data - RS485 In/Out Required Ground Ground Required Table 2-3 RS485 Signal Lines ⚫ RS422 Signal Lines...
SMG-5521 User Manual Ver. 1.0 2.4.4 LED LED operations according to each state are as follows: When the supplied power is stable: PWR When the supplied power is NOT stable: PWR When the script is running: RUN When the script is NOT running: RUN...
SMG-5521 User Manual Ver. 1.0 2.4.5 Function Button This button is used to implement a factory reset. 2.4.6 Setup Port This port is used for making a connection with a PC via USB cable. - 12 - https://www.ezTCP.com...
SMG-5521 User Manual Ver. 1.0 Preparation 3.1 Installing the Setting Tool You need a program which is called spFinder to use this product. Download the program on our web site and install it on your PC. Functions of the spFinder are as follows: ⚫...
SMG-5521 User Manual Ver. 1.0 Settings 4.1 IP Network 4.1.1 Obtain an IP address automatically This product can automatically obtain an IP address by DHCP. A DHCP server is required to use this. Figure 4-1 Obtain an IP address automatically ⚫...
SMG-5521 User Manual Ver. 1.0 4.1.2 Use a static IP address You can set a static IP address to this product. Figure 4-2 Use a static IP address ⚫ Select the [Use static IP address]. ⚫ Set the [Local IP address], [Subnet mask], [Gateway IP address] and [DNS IP address].
SMG-5521 User Manual Ver. 1.0 4.2 General Figure 4-3 General 4.2.1 Comment This setting is for storing the product description. The maximum setting size of this item is 32 bytes. - 16 - https://www.ezTCP.com...
SMG-5521 User Manual Ver. 1.0 4.3 Security Figure 4-4 Security 4.3.1 Password Both ID and password are required to access this product. Note that changing the default password to another is highly recommended for security. The password should be longer than 8 characters.
SMG-5521 User Manual Ver. 1.0 ⚫ Remote access If this item is checked, the product can be connected from the remote network. For security, this item is unchecked by default. 4.3.4 Client ID The Unique ID which is used to register the device under your account in Sollae Cloud.
SMG-5521 User Manual Ver. 1.0 Management 5.1 Checking Status This is a function to view the current status of the product. Information in the [Status] window automatically updated every second. After searching connecting the product with spFinder, press the [Status] button to display this window.
SMG-5521 User Manual Ver. 1.0 5.1.2 Communication Status ⚫ Communication Status Window This area shows some communication status of your product. This area is refreshed every second. Figure 5-2 Communication Status Window ⚫ REGISTRATION STATE The registration state indicates whether the device is registered on Sollae Cloud under an account or not.
Page 22
SMG-5521 User Manual Ver. 1.0 ⚫ DEVICE STATE The device operation state. Status STARTING UPDATING INFORMATION TO CLOUD FAILED TO UPDATE INFORMATION TO CLOUD DEVICE IS UNREGISTERED TO AN USER CONNECTING MQTT SERVER MQTT CLOSED MQTT CONNECTED TO CLOUD MQTT PING TO CLOUD...
SMG-5521 User Manual Ver. 1.0 ⚫ Polling Query Num The number of Modbus and HMI query set via Sollae Cloud for the device. 5.1.3 Timeout This is the timeout display function that appears in the upper right of the status window.
SMG-5521 User Manual Ver. 1.0 5.2 Firmware Change New firmware can be released when adding functions or fixing bugs. If you are using old firmware, you can upgrade it to the latest version. Firmware can be upgraded online or manually via spFinder.
SMG-5521 User Manual Ver. 1.0 5.2.2 Manual Upragde Figure 5-4 Manual Upgrade ⚫ Download a Firmware file to your PC. ⚫ Search and connect to your product by spFinder. ⚫ Click [Advanced] > [Firmware Change] menu. ⚫ Select to [Manual upgrade] on the [Firmware Upgrade] window.
SMG-5521 User Manual Ver. 1.0 5.3 Console The console function analyzes and displays the Modbus frames sent and received by the product. After searching and connecting the product with spFinder, click [Console] in the [Advanced] menu to display the console window. When you open this window, the spFinder connects to the product and keeps the connection until you close the window or time out.
SMG-5521 User Manual Ver. 1.0 5.3.2 FW Log Tab This tab displays the log message from Firmware. 5.3.3 Timeout This is the timeout display function that appears in the upper right of the console window. When this time reaches zero, the connection between spFinder and the product is lost.
SMG-5521 User Manual Ver. 1.0 5.5 Reboot a Product This function is for rebooting a product. Figure 5-7 Reboot a Product 5.6 Factory Reset Performing the Factory Reset, you can restore all the settings to the default including the password. Follow the procedure below by checking the status of RUN LED.
Technical Support and Warranty 6.1 Technical Support If you have any question regarding operation of the product, visit Customer Support FAQ corner and the message board on Sollae Systems’ web site or send us an email at the following address: ⚫ E-mail: support@eztcp.com...
⚫ Specifications of the product are subject to change without prior notice for performance improvement. ⚫ Sollae Systems does not guarantee successful operation of the product if the product was used under conditions deviating from the product specifications. ⚫ Reverse engineering of firmware and applications provided by Sollae Systems is prohibited.
(including, without limitation, damages for loss of profit, operating cost for commercial interruption, loss of information, or any other financial loss) from the use or inability to use the SMG-5521 even if Sollae Systems Co., Ltd. or its distributors have been informed of such damages.
à leur propriétaire et Fabricant respectif. ⚫ Conditions d’utilisations et limite de responsabilité En aucun cas Sollae Systems Co., Ltd. ou un de ses distributeurs ne pourra être tenu responsable de dommages quels qu'ils soient (intégrant, mais sans limitation, dommages...
Page 33
SMG-5521 sans que la responsabilité de Sollae Systems Co., Ltd. et de ses distributeurs ne puissent être mise en cause, ni que le boîtier SMG-5521 puisse être échangé au titre de la garantie.
Need help?
Do you have a question about the SMG-5521 and is the answer not in the manual?