SMG-5420 User Manual Ver. 1.6 This symbol, found on your product or on its packaging, indicates that this product should not be treated as household waste when you wish to dispose of it. Instead, it should be handed over to an applicable collection point for the recycling of electrical and electronic equipment.
SMG-5420 User Manual Ver. 1.6 Modbus Overview 1.1 Modbus Modbus is a serial communications protocol originally published by Modicon (now Schneider Electric) in 1979 for use with its programmable logic controller (PLCs). As a matter of fact, Modbus has become a standard communication protocol.
SMG-5420 User Manual Ver. 1.6 1.2 Modbus Gateway Figure 1-1 Modbus Gateway Devices that use Modbus/TCP cannot directly communicate with devices that use serial line Modbus protocols. Because not only the physical interfaces are different but also the protocols are not compatible. To facilitate communication between the two devices, an additional device is required to route the Modbus data from each device.
Product Overview 2.1 Product Overview SMG-5420 is an industrial Modbus Gateway that converts and routes Modbus data between the serial line and Modbus/TCP. This can help communicate between Modbus master (or slave) of serial line and Modbus slave (or master) of network.
Page 8
SMG-5420 User Manual Ver. 1.6 Security Password Dimension Size 94mm x 57mm x 23mm Weight about 67g Operating Environment Input Voltage DC5V±0.5V Protection Reverse Voltage Protection / Surge Protection Current Consumption typically, 145mA Operating -40℃ ~ +85℃ Temperature Storage Temperature -40℃...
SMG-5420 User Manual Ver. 1.6 2.4 Interface Figure 2-1 Interface 2.4.1 Power SMG-5420 requires DC5V power supply whose specification is as follows: Figure 2-2 Power - 8 - https://www.ezTCP.com...
SMG-5420 User Manual Ver. 1.6 2.4.2 Ethernet SMG-5420 provides 10/100Mbps Ethernet. The pin assignment is as follows: Figure 2-3 Ethernet 2.4.3 Serial Port SMG-5420 has a 3.5mm pitch 6-pole terminal block for connecting serial devices. Figure 2-4 Serial Port ⚫ Port Specification Parameter Value...
Page 11
SMG-5420 User Manual Ver. 1.6 ⚫ RS485 Signal Lines Label Name Description Level Wiring TRX + Data + RS485 In/Out Required TRX - Data - RS485 In/Out Required Ground Ground Required Table 2-3 RS485 Signal Lines ⚫ RS422 Signal Lines...
SMG-5420 User Manual Ver. 1.6 2.4.4 LED LED operations according to each state are as follows: When the supplied power is stable: PWR When the supplied power is NOT stable: PWR When the script is running: RUN When the script is NOT running: RUN...
SMG-5420 User Manual Ver. 1.6 2.4.5 Function Button This button is used to implement a factory reset. 2.4.6 Setup Port This port is used for making a connection with a PC via USB cable. - 12 - https://www.ezTCP.com...
SMG-5420 User Manual Ver. 1.6 Preparation 3.1 Installing the Setting Tool You need a program which is called spFinder to use this product. Download the program on our web site and install it on your PC. Functions of the spFinder are as follows: ⚫...
SMG-5420 User Manual Ver. 1.6 Settings 4.1 IP Network 4.1.1 Obtain an IP address automatically This product can automatically obtain an IP address by DHCP. A DHCP server is required to use this. Figure 4-1 Obtain an IP address automatically ⚫...
SMG-5420 User Manual Ver. 1.6 4.1.2 Use a static IP address You can set a static IP address to this product. Figure 4-2 Use a static IP address ⚫ Select the [Use static IP address]. ⚫ Set the [Local IP address], [Subnet mask], [Gateway IP address] and [DNS IP address].
SMG-5420 User Manual Ver. 1.6 4.2 General Figure 4-3 General 4.2.1 Comment This setting is for storing the product description. The maximum setting size of this item is 32 bytes. 4.2.2 Transmission Mode This is the setting to select the communication protocol for the serial line. It should be configured according to the protocol of the connected serial device.
SMG-5420 User Manual Ver. 1.6 4.2.4 Serial Parameter Available Values Default Values Data Bits 8 or 7 (7-bit is only available on using Parity) Stop Bits 1 or 2 Parity None, Even, Odd, Mark or Space None Table 4-2 Serial 4.2.5 Modbus...
SMG-5420 User Manual Ver. 1.6 ⚫ Response Timeout (Unit: ms) This setting defines expiration time for a Modbus query. The unit of this setting is millisecond. It can be set a number between 20 and 30,000, and the default value is 500.
Page 20
SMG-5420 User Manual Ver. 1.6 ⚫ Multiple Connection This item enables multiple TCP connections. When this item is set to Disable, only one TCP session (TCP0) can be used. If this item is set to Enable, the rest of TCP sessions (TCP1 to 3) are activated. It means you can use 4 sessions at the same time.
SMG-5420 User Manual Ver. 1.6 4.3 Security Figure 4-6 Security 4.3.1 Password Both ID and password are required to access this product. Note that changing the default password to another is highly recommended for security. The password should be longer than 8 characters.
SMG-5420 User Manual Ver. 1.6 ⚫ Remote access If this item is checked, the product can be connected from the remote network. For security, this item is unchecked by default. 4.3.4 Client ID This is NOT available for this product.
SMG-5420 User Manual Ver. 1.6 Management 5.1 Checking Status This is a function to view the current status of the product. Information in the [Status] window automatically updated every second. After searching connecting the product with spFinder, press the [Status] button to display this window.
SMG-5420 User Manual Ver. 1.6 5.1.2 Communication Status ⚫ Communication Status Window This area shows some communication status of your product. This area is refreshed every second. Figure 5-2 Communication Status Window ⚫ TCP STATE Status Description LISTEN Listen CLOSED...
SMG-5420 User Manual Ver. 1.6 ⚫ MODBUS STATISTICS Item Description RX0~3 Statistics of incoming data from the TCP TX0~3 Statistics of outgoing data to the TCP Statistics of incoming data from the serial Statistics of outgoing data to the serial...
SMG-5420 User Manual Ver. 1.6 5.2 Firmware Change New firmware can be released when adding functions or fixing bugs. If you are using old firmware, you can upgrade it to the latest version. Firmware can be upgraded online or manually via spFinder.
SMG-5420 User Manual Ver. 1.6 5.2.2 Manual Upragde Figure 5-4 Manual Upgrade ⚫ Download a Firmware file to your PC. ⚫ Search and connect to your product by spFinder. ⚫ Click [Advanced] > [Firmware Change] menu. ⚫ Select to [Manual upgrade] on the [Firmware Upgrade] window.
SMG-5420 User Manual Ver. 1.6 5.3 Console The console function analyzes and displays the Modbus frames sent and received by the product. After searching and connecting the product with spFinder, click [Console] in the [Advanced] menu to display the console window. When you open this window, the spFinder connects to the product and keeps the connection until you close the window or time out.
SMG-5420 User Manual Ver. 1.6 ⚫ dump on Pressing this button starts printing communication data to the Output tab ⚫ dump off Pressing this button stops printing communication data to the Output tab ⚫ reset stat Press this button to reset all the communication status information statistics of the product.
SMG-5420 User Manual Ver. 1.6 5.5 Factory Reset Performing the Factory Reset, you can restore all the settings to the default including the password. Follow the procedure below by checking the status of RUN LED. 1. Press and immediately release the function button.
Technical Support and Warranty 6.1 Technical Support If you have any question regarding operation of the product, visit Customer Support FAQ corner and the message board on Sollae Systems’ web site or send us an email at the following address: ⚫ E-mail: support@eztcp.com...
⚫ Specifications of the product are subject to change without prior notice for performance improvement. ⚫ Sollae Systems does not guarantee successful operation of the product if the product was used under conditions deviating from the product specifications. ⚫ Reverse engineering of firmware and applications provided by Sollae Systems is prohibited.
(including, without limitation, damages for loss of profit, operating cost for commercial interruption, loss of information, or any other financial loss) from the use or inability to use the SMG-5420 even if Sollae Systems Co., Ltd. or its distributors have been informed of such damages.
à leur propriétaire et Fabricant respectif. ⚫ Conditions d’utilisations et limite de responsabilité En aucun cas Sollae Systems Co., Ltd. ou un de ses distributeurs ne pourra être tenu responsable de dommages quels qu'ils soient (intégrant, mais sans limitation, dommages...
Page 35
SMG-5420 sans que la responsabilité de Sollae Systems Co., Ltd. et de ses distributeurs ne puissent être mise en cause, ni que le boîtier SMG-5420 puisse être échangé au titre de la garantie.
SMG-5420 User Manual Ver. 1.6 Revision History Date Version Description Author 2019.06.20. 1. Initial release Roy Lee 2019.07.08. 1. Correct some errors Roy Lee 2020.01.23. 1. Add Upgrading Firmware chapter Roy Lee 2. Apply changes of spFinder UI 3. Apply changes of parameters: Slave Address, Unit ID 4.
Need help?
Do you have a question about the SMG-5420 and is the answer not in the manual?
Questions and answers