1. Introduction
TRP-C08 can be stable running in the industrial environment.
It provides USB port protection when it detected unusual currents.
TRP-C08 provides RS422/485 line surge protection and RS232/422/485 with a photo couple
between USB ports.
TRP-C08 can be easy to use, users have no worries about setting the serial data format and
RS485 flow control, and how to wire RS422/485, everything is auto-detectable.
1.1.
Features
Full compliance with the USB V1.0 and 2.0 specification.
Fixed com port function no matter which USB port plug
USB port protection when detecting unusual currents.
Auto UART data format detecting.
Auto direction flow control on RS-485.
Programmable baud rate from 75 bps to 6 Mbps
RS232/422/485 Support 3KV isolation
256 byte buffer for upstream and downstream data flow.
Direct power from USB port , no external power necessary.
3000V DC isolated protection.
Surge protection on RS422/485 data lines.
Power/TX/RX mode LED indicator.
DIN rail or panel mount support.
Linux 5.5 above embedded.
Driver support: Android/Windows 8/8.1/ 98/ME/2000/XP/7/CE3.0/WIN 10/WIN 11, and Linux, and Mac OS.
Fully compatible with SCB-C08.
1-2. Specifications
USB interface: Fully compliant with V1.0, 2.0 specification.
USB to serial bridge controller; Prolific PL2303GC.
RS-232 signal: 5 full-duplex (TXD, RXD, CTS, RTS, GND).
RS-422 signal: Differential 4 full-duplex wires (TX+, RX+, TX-, RX-).
RS-485 signal: Differential 2 half-duplex wires (D+, D-).
Data Format: Asynchronous data with all common combination of bits, parity, stop.
Parity type: None, odd, even mark, space.
Data bit: 5, 6, 7, 8 or 16.
Stop bits: 1, 1.5, 2.
Cable: USB type A to type B.
Communication speed: 75~128KBbps.
RS-422/485 line protection: Against surge, short circuit, and voltage peak.
Transmission distance: RS-422/485 Up to 4000ft (1200M ).
Connection type: Screw terminal accepts AWG #12~30 wires.
Signal LED: Power on, TX, RX.
Direct power from USB port.
Power consumption: 1.2W.
Isolation voltage: 3000V DC.
Operating environment: -10 to 50℃ .
Storage temperature: -20 to 70℃.
Humidity: 10-90% Non-condensing.
Dimension: 151mm X 75mm X 26mm .
Weight: 375g .