Page 1
MODEL – 40S All information included in this publication is based on the latest information available at the time of printing. Pentair reserves the right to make changes at any time without notice and without incurring any obligation whatsoever. Photocopying of this...
Page 2
DANGER – HIGH PRESSURE DEVICE This vessel may cause loss of life, severe bodily harm, or property damage if not correctly installed, operated and maintained. Read and understand all guidelines given in this bulleting before attempting to open, operate or service this vessel. Failure to follow these guidelines and observe every precaution will result in malfunction and could result in catastrophic failure.
Page 3
CODED 40S: 300 / 450 / 600 psig Dwg Ref Qty Per Item # Description Materials Shell Filament Wound Epoxy/Glass composites - Shell Head locking grooves integrally wound in Order place. Section F/C Port SA-351 CF8M Ethylene Propylene – O-ring 196596 F/C Port Seal Head...
Page 4
NON-CODED 40S: 300 / 450 / 600 PSIg Dwg Ref Qty Per Item # Description Materials Shell Filament Wound Epoxy/Glass composites Shell - Head locking grooves integrally wound in Order place. Section F/C Port SA-351 CF8M Ethylene Propylene – O-ring 196596 F/C Port Seal Head...
INSTALLATION Regardless of when or by whom your vessel may have been installed, there are a few quick checks you should make before use. Check that each vessel is: • Mounted with compliant material (Polyurethane saddle) between the fiberglass shell and any rigid frame.
Page 6
vessel until the end of the ring is resting in the end margin of the shell. 2. Remove the 4” retaining ring from the stainless groove in the shell by rotating your finger behind the ring as it continues to exit the groove. Removal of Retaining Ring 3.
Page 7
Where upstream. conflicts exist, contact element 6. Install the interconnectors between manufacturer Pentair Water multiple elements as each succeeding clarification. element is installed. Removing Elements CAUTION 1. Remove heads from both ends of System malfunctions and element damage...
Page 8
REPLACING ELEMENTS & CLOSING THE VESSEL (Cont…) 4. Install adapter into one end plug. At downstream end of vessel, orient end plug ports into desired position and push plug fully into vessel. A sharp, forceful thrust may be needed to enter plug seal into the vessel bore.
Page 9
HEAD DISASSEMBLY - CODED NOTE Head Rebuilding should be performed in a clean work area. Dust or dirt on O- rings or other parts can scratch inner surfaces, with subsequent leakage. 1. Using a small screwdriver or similar tool Remove the Sealing Plate by pressing it remove the Plug Seal.
HEAD DISASSEMBLY – NON-CODED Using a small screwdriver or similar tool Remove the PWT / Adapter Seal from the remove the Plug Seal. However, do not permeate Port using a small screwdriver damage the sealing surface in any way or similar tool. However, do not damage as it may lead to leakage.
Page 11
HEAD ASSEMBLY - CODED 1. Use only head components in as-new Please ensure that the side of the sealing Plate with the Permeate Port seal faces the condition. Use new O-rings each time permeate port hub. the head is assembled. 2.
Page 12
Plastic parts: examine for cracking, softening, or discoloring. This may indicate chemical attack of the material. Defective parts must be replaced. Alternate material may be required. Contact your supplier or Pentair Water for assistance. Metal parts: check for corrosion, scratches, dents, cracks, or other damages to insert ring and spiral retaining ring.
Use of components damaged by corrosion can cause catastrophic failure. 3. Seals should be replaced as necessary each time the vessel is serviced. Any parts that need to be replaced are available from your supplier or from Pentair. SHIMMING 1. Shutdown the system and remove both vessel fiberglass endcaps.
Need help?
Do you have a question about the CodeLine 40S and is the answer not in the manual?
Questions and answers