AERMEC RV Technical And Installation Booklet

AERMEC RV Technical And Installation Booklet

Air to water chillers and heat pumps

Advertisement

Quick Links

Refrigeratori aria acqua e pompe di calore
con compressori mono-vite
Air to water chillers and heat pumps
with single screw compressors
RV - RVH
3
H
H
H
H
H
H
H
H
H
H
H
H
H
H
PRELIMINARY
Sostituisce il:
Replace:
683111_01 / 0305
IRVPW
0412
6831111_02

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RV and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AERMEC RV

  • Page 1 Refrigeratori aria acqua e pompe di calore con compressori mono-vite Air to water chillers and heat pumps with single screw compressors RV - RVH IRVPW Sostituisce il: 0412 Replace: 6831111_02 683111_01 / 0305 PRELIMINARY...
  • Page 2: Dichiarazione Di Conformita

    Noi, firmatari della presente, dichiariamo sotto la nostra equipment described as follows: esclusiva responsabilità che l'insieme in oggetto così definito: AIR TO WATER CHILLER AND HEAT PUMP RV REFRIGERATORE D'ACQUA E POMPA DI CALORE RV complies with following provisions: risulta : 1.
  • Page 3 • AERMEC S.p.A. declina ogni responsabilità per qualsiasi • AERMEC S.p.A. declines all responsibility for any dama- danno dovuto ad un uso improprio della macchina, ad ge whatsoever caused by improper use of the machine, una lettura parziale o superficiale delle informazioni and partial or superficial knowledge of the information contenute in questo manuale.
  • Page 4: Versioni Disponibili

    Le unità della serie RV sono refrigeratori d'acqua per impianti tecno- units are supplied also in heat pump version RVH that produce logici fornibili anche nei modelli RV-H a pompa di calore che per- hot water for heating. RV unit features gas-compressed air-con- mettono di produrre acqua calda per il riscaldamento.
  • Page 5 ATTENZIONE: il simbolo ° rappresenta le opzioni standard. The RVB heat pump (H) do not come with, low temperatu- Gli RV a pompa di calore (H) non prevedono : bassa tempe- re versions (Y), high temperature versions (A) (the HL ratura (Y), alta temperatura (A) (già...
  • Page 6: Componenti Principali

    COMPONENTI PRINCIPALI MAIN COMPONENTS 1 Scambiatore lato aria • Air side exchanger 9 Gruppo ventilante • Fan section 2 Pressostato • Pressureswitch 10 Struttura portante • Channel frame 3 Filtro deidratatore • Filter drier 11 Quadro elettrico • Switchboard 4 Spia del liquido • Sight-glass 12 Tastiera di comando •...
  • Page 7 COPERTURA DI PROTEZIONE ACUSTICA The cover reduces the sound level of unit operation while Di serie su tutta le versioni RV, é costituita da un vano in protecting the compressors against atmospheric agents. lamiera zincata di forte spessore e rivestita internamente di materiale fonoassorbente.
  • Page 8: Safety And Control Devices

    - phase sequence and MIN-MAX voltage control relay CONTROL COMPONENTS ORGANI DI REGOLAZIONE Electronic regulation of the RV refrigerators comprises a con- La regolazione elettronica sui refrigeratori RV è costituita da trol card for each compressor, which are networked una scheda di controllo per ogni compressore collegate tra together, and a control panel with display.
  • Page 9: Microprocessor Board

    general machine connections are made to the master board allarmi relativi al compressore che comanda, mentre solo only. sulla scheda master sono collegati quelli generali della mac- china. MICROPROCESSOR BOARD SCHEDA A MICROPROCESSORE Functions: • Inlet water temperature control by thermostatic and Funzioni svolte: capacity step control.
  • Page 10 digital input and output status display; visualizzazione codice software e data di creazione; analogue readout and digital output value displa visualizzazione dello stato degli ingressi e uscite digitali; visualizzazione valori delle letture analogiche e uscite digitali; – COMPRESSOR START-UP/SHUTDOWN – ACCENSIONE - SPEGNIMENTO COMPRESSORI The boards control compressor start-up and shutdown according to the water temperature detected by the probe Le schede gestiscono l'accensione e lo spegnimento dei...
  • Page 11 = indica che l’accessorio può essere abbinato solo alle versioni silenziate (L) solo freddo. = indica che l’accessorio può essere abbinato a tutti gli RV con l’esclusione delle versioni silenziate (L) solo freddo. N.B. = le parentesi graffe, su alcuni modelli, mostrano la necessità di montare la combinazione degli accessori indicati.
  • Page 12 “0601 - 1802” REFRIGERA ORI • CHILLERS R407C “0601 - 1802” REFRIGERA ORI • CHILLERS R407C RAFFREDDAMENTO • COOLING 0601 0701 0901 1101 1401 1601 1202 1402 1602 1802 Potenzialità frigorifera • Cooling capacity [kW] Potenza assorbita totale • Total input power [kW] 2,57 2,51...
  • Page 13 “0601 - 1802” REFRIGERA ORI • CHILLERS R407C “0601 - 1802” REFRIGERA ORI • CHILLERS R407C DATI ELETTRICI • ELECTRICAL DATA 0601 0701 0901 1101 1401 1601 1202 1402 1602 1802 Corrente assorbita • Current absorption Corrente max. • Max.current Corrente di spunto •...
  • Page 14 RV 1602 A - E - H RV 1802 L - A - E - H ø 80 Mod. Dimensioni • Dimensions Attacchi•Connections Ø IN Ø AUT 5.100 1.551 1.551 2.325 2.200 V 3” V 3” 1602 A EH 5.100 1.551...
  • Page 15 Technical data shown in this booklet are not binding. I dati tecnici riportati nella presente documentazione non sono impe- Aermec S.p.A. shall have the right to introduce at any time whatever gnativi. modifications deemed necessary to the improvement of the product.