Page 1
AERMEC S.P.A. BEVILACQUA (VERONA) ITALY SCHEMA ELETTRICO WIRING DIAGRAM NYB 500 RP NORME PROTEZIONE PROGETTAZIONE TENSIONE Elettrica 460V 60Hz ESERCIZIO TENSIONE SERIE 230V 60Hz COMANDI UBICAZIONE NOME LOGICO DISEGNO 5554025_00 TENSIONE SEGNALI COMMITTENTE Sabik PROGETTATO CON SISTEMA CAD/CAE š5554025_00+œ SCHEMA FUNZIONALE...
Page 2
NA NC NA NC Line 460V 3Ph 60Hz MTC1 MTC2 I> I> I> I> I> I> COMPRESSORE COMPRESSOR DATA 25/01/2016 NYB 500 RP POTENZA DISEGN. AERMEC S.P.A. Crivellaro DATA FOGL. 25/01/2016 BEVILACQUA (VERONA) ITALY 5554025_00 POWER REV. MODIFICA DATA DISEGNATO VERIFICATO APPROV.
Page 3
0Vac NA NC 630VA MTVA MTVB NA NC NA NC I> I> I> I> I> I> VENTILATORE DATA 25/01/2016 NYB 500 RP POTENZA DISEGN. AERMEC S.P.A. Crivellaro DATA FOGL. 25/01/2016 BEVILACQUA (VERONA) ITALY 5554025_00 POWER REV. MODIFICA DATA DISEGNATO VERIFICATO APPROV.
Page 4
30° 50VA RAP1 0Vac 24Vac RESISTENZA CP CASING HEATER RAP2 RAP1 RAP2 DATA 25/01/2016 NYB 500 RP CIRCUITO AUSILIARIO DISEGN. AERMEC S.P.A. Crivellaro DATA FOGL. 25/01/2016 BEVILACQUA (VERONA) ITALY 5554025_00 Auxiliary circuit REV. MODIFICA DATA DISEGNATO VERIFICATO APPROV. De Togni...
Page 5
24Vac 24Vac RAP1 RAP2 MTVA MTC1 MTC2 MTVB 0Vac 0Vac DATA 25/01/2016 NYB 500 RP Collegamento sicurezze DISEGN. AERMEC S.P.A. Crivellaro DATA FOGL. 25/01/2016 BEVILACQUA (VERONA) ITALY 5554025_00 Safety connection REV. MODIFICA DATA DISEGNATO VERIFICATO APPROV. De Togni...
Page 6
24Vac 24Vac 0Vac 0Vac DATA 25/01/2016 NYB 500 RP Collegamento sicurezze DISEGN. AERMEC S.P.A. Crivellaro DATA FOGL. 25/01/2016 BEVILACQUA (VERONA) ITALY 5554025_00 Safety connection REV. MODIFICA DATA DISEGNATO VERIFICATO APPROV. De Togni...
Page 7
CONTATTI LIBERI RAP1 VSL1 LINEA LINE MAX 50V 1A MAX 50V 1A DATA 25/01/2016 NYB 500 RP COLLEGAMENTO CARICHI DISEGN. AERMEC S.P.A. Crivellaro DATA FOGL. 25/01/2016 BEVILACQUA (VERONA) ITALY 5554025_00 Load connection REV. MODIFICA DATA DISEGNATO VERIFICATO APPROV. De Togni...
Page 8
RAP2 VSL2 DATA 25/01/2016 NYB 500 RP COLLEGAMENTO CARICHI DISEGN. AERMEC S.P.A. Crivellaro DATA FOGL. 25/01/2016 BEVILACQUA (VERONA) ITALY 5554025_00 Load connection REV. MODIFICA DATA DISEGNATO VERIFICATO APPROV. De Togni...
Page 9
SGP1 TAP1 TBP1 SGP2 TAP2 TBP2 MULTI IN MULT Collegare segnale senza riferimento (flottante) Connect signal without reference (floating) DATA 25/01/2016 NYB 500 RP COLLEGAMENTO SENSORI DISEGN. AERMEC S.P.A. Crivellaro DATA FOGL. 25/01/2016 BEVILACQUA (VERONA) ITALY 5554025_00 Analogic connection REV.
Page 10
DATA 25/01/2016 NYB 500 RP LEGENDA DISEGN. AERMEC S.P.A. Crivellaro DATA FOGL. 25/01/2016 BEVILACQUA (VERONA) ITALY 5554025_00 LEGEND REV. MODIFICA DATA DISEGNATO VERIFICATO APPROV. De Togni...
Page 11
NC self-operating thermal switch Contattore tripolare di potenza NA 071302-3F Three-pole NO contact of a contactor Elemento riscaldante 040112 E... Heating element DATA 25/01/2016 NYB 500 RP Riepilogo simboli DISEGN. AERMEC S.P.A. Crivellaro DATA FOGL. LS-1 25/01/2016 BEVILACQUA (VERONA) ITALY...
Page 13
Contatto NC sensibile alla pressione 070701PC SP... NC contact actuated by pressure Termostasto di sicureza NA - chiude all'aumentare 070701TNA Safety thermostat NO - close un rise DATA 25/01/2016 NYB 500 RP Riepilogo simboli DISEGN. AERMEC S.P.A. Crivellaro DATA FOGL. LS-3 25/01/2016...
Page 14
DESCRIPTION DESIGNATION Trasformatore a 2 avvolgimenti 060902 TM... Transformer with 2 windings Elettrovalvola chiusa 071502B YV... Closed solenoid valve DATA 25/01/2016 NYB 500 RP Riepilogo simboli DISEGN. AERMEC S.P.A. Crivellaro DATA FOGL. LS-4 25/01/2016 BEVILACQUA (VERONA) ITALY 5554025_00 Symbol summary REV.
Page 15
MTVA MTVA MTVA MORSETTIERA QUADRO TERMINAL BOARD DATA 25/01/2016 NYB 500 RP RIEPILOGO MORSETTI DISEGN. AERMEC S.P.A. Crivellaro DATA FOGL. M1-001 25/01/2016 BEVILACQUA (VERONA) ITALY 5554025_00 Summary terminals REV. MODIFICA DATA DISEGNATO VERIFICATO APPROV. De Togni...