Carel Thermostat - Igloo KING EVO Instruction Manual

Cooling equipment
Table of Contents

Advertisement

Available languages

Available languages

en

7.2. CAREL thermostat

Fig.16. Carel thermostat panel
1
2
3
4
5
LEDs ON THE DISPLAY
LED 1 on – Compressor: the symbol is visible when the compressor is running. It is blinking when the compressor start is
delayed by the protection procedure. In the continuous mode it blinks in the cycle: two blinks – pause.
LED 2 on – Fan: the symbol is visible when the evaporator fans are on. The symbol blinks when the fan start is delayed
by an external deactivation or when another procedure is in progress.
LED 3 on – Defrosting: the symbol is visible when the defrosting procedure is activated. The symbol blinks when the
defrosting is delayed by an external deactivation or when another procedure is in progress.
LED 4 on – Alarm: the symbol is visible when an alarm is active
LED 5 on – current temperature inside the equipment (with one decimal place)
NASTAWA ŻĄDANEJ TEMPERATURY
- press for 1 second :
; the value will be displayed on the screen;
- increase or decrease the value using
and
- press again
to confirm the setpoint;
MANUAL DEFROSTING
Defrosting is performed automatically. You can start it manually anytime, however, by pressing and holding
for at
least 5 seconds. LED 1 is blinking during the manual defrosting.
* More on www.alfaco.pl
23
I G L O O . P L
.
N
N
z
T
XX

Advertisement

Table of Contents