Specifications - Dometic Penguin 621815 Installation Instructions Manual

Roof top air conditioner, roof top heat pump
Table of Contents

Advertisement

Model No.
Nominal
Capacity
(BTU HR)
Cooling
621815.331
13,500
621815.336
13,500
621816.331
15,000
621816.336
15,000
621835.331
13,500
621835.336
13,500
631815.331
13,500
631815.336
13,500
631816.331
15,000
631816.336
15,000
*
For wire length over 24 ft., consult the National Electric Code for proper sizing.
** Dometic, LLC gives gENERAL guidelines for generator requirements. These guidelines come from experiences people
have had in actual applications. When sizing the generator, the total power usage of your recreational vehicle must be
considered. Keep in mind generators lose power at high altitudes and from lack of maintenance.
*** CIRCUIT PROTECTION: Time Delay Fuse or HACR Circuit Breakers Required.

SPECIFICATIONS

Electrical
Compressor
Compressor
Rating
Rated Load
Locked
120 VAC
Amps
Rotor
60Hz. 1PH
Amps
12.4
60.0
12.4
60.0
12.0
64.0
12.0
64.0
12.4
60.0
12.4
60.0
12.4
60.0
12.4
60.0
12.0
64.0
12.0
64.0
Fan Motor
Fan Motor
Refrigerant
Rated Load
Locked
R-22
Amps
Rotor
(Oz.)
Amps
3.5
10.0
15.2
3.5
10.0
15.2
3.3
8.2
20.0
3.3
8.2
20.0
3.5
10.0
15.2
3.5
10.0
15.2
3.5
10.0
23.5
3.5
10.0
23.5
3.3
8.5
20.0
3.3
8.5
20.0
3
Minimum
AC Circuit
Minimum
Wire Size*
Protection
Generator
12 AWG
***Installer
Size**
Copper
Supplied
1 Unit / 2 Units
Up to 24'
20 Amp
3.5 KW / 5.0 KW
20 Amp
3.5 KW / 5.0 KW
20 Amp
3.5 KW / 5.0 KW
20 Amp
3.5 KW / 5.0 KW
20 Amp
3.5 KW / 5.0 KW
20 Amp
3.5 KW / 5.0 KW
20 Amp
3.5 KW / 5.0 KW
20 Amp
3.5 KW / 5.0 KW
20 Amp
3.5 KW / 5.0 KW
20 Amp
3.5 KW / 5.0 KW