579/595 series brisk air, quick cool roof top air conditioners used with cooling & furnace, cooling, furnace & heat strip remote comfort control kit ducted (19 pages)
This unit can be installed by one person with brief help from additional personnel. Use these instructions to ensure a properly installed, and properly functioning product. Dometic Corporation reserves the right to modify appearances and specifications without notice. TABLE OF CONTENTS INTRODUCTION ..................................2...
● This product MUST be [installed / serviced] by a qualified service technician. ● Do NOT modify this product in any way. Modifica- tion can be extremely hazardous. ● Do NOT add any devices or accessories to this product except those specifically authorized in writing by Dometic Corporation.
For wire length over 24 ft., consult the National Electrical Code for proper sizing. ** Dometic Corporation gives GENERAL guidelines for generator requirements. These guidelines come from experiences people have had in actual applications. When sizing the generator, the total power usage of your RV must be considered.
SPECIFICATIONS Table - Air Distribution Duct Sizing & Design Air Distribution Duct Sizing & Design Chart For Ducted Applications Return Air Cover Model 3105007.XXX 3105935.XXX Roof Cavity Depth 2 in - 2 1/2 in Max. Duct Cross Section Area (inside) 21 in Min.
INSTALLATION INSTRUCTIONS FIG. 2 Dimensions Are Nominal Dimensions Are Nominal Model FIG. 4 520300 17″ 520310 520315 3/4″ 520316 13″ 17″ 1-1/2″ 29-7/8″ Roof 39-5/8″ Opening 18″ Roof Opening Center Line Of Unit 17″ 1-3/4″ Front 1-1/4″ Keep This Area Free Of Obstructions 1-1/2″...
Power Supply Wiring Opening dirt accumulation on unit cooling surface. 6. Air Distribution System Installation a. Dometic Corporation recommends the basic configuration shown in (FIG. 7), for installing Air Distribution Duct Sizing & Design this system. We have found by testing, that...
INSTALLATION INSTRUCTIONS Duct Size And Requirements For 3105007.XXX And 3105935.XXX RAG FIG. 7 Register Required Registers 4 Min - 8 Max. (Per Unit) 14 Sq. In. Free Area Per Register Wiring Requirements 4. If system includes a gas furnace, route two 18- 22 AWG thermostat wires from the furnace to 1.
INSTALLATION INSTRUCTIONS Thermostat Installation Placing Unit On Roof 1. R emove the unit from the carton and discard 1. LCD SZ System carton. W ire colors listed for the communication 2. LIFTING HAZARD. Use proper cable (3 conductor cable) match the wire colors in the unit wire harness and the wire lifting technique and control when lifting product.
INSTALLATION INSTRUCTIONS Installation Preparation FIG. 12 Control 1. C heck gasket alignment of the unit over the Wires roof opening and adjust if necessary. Unit may be moved from below by slightly lifting. See (FIG. 10). FIG. 10 Center Unit From Below Gasket 120 Vac Power Supply...
Page 11
INSTALLATION INSTRUCTIONS 6. Installation Of Divider Plate d. With slight pressure push the divider plate against the double-sided tape on the ceiling a. Measure the ceiling to roof thickness: template. ● If distance is 2.0″ - 3-3/4″, remove perfo- rated tab from divider plate. See (FIG. 14). e.
INSTALLATION INSTRUCTIONS LCD SZ System Low Voltage Wire FIG. 17 Connections Freeze Control 1. A ll Heat Pump Electronic Control Kit Systems Sensor a. Plug the outdoor temperature sensor from the unit into the white 2 pin matching con- nector in the electronic control box.
INSTALLATION INSTRUCTIONS Installing Return Air Cover 1. R emove the return air grille from the return air cover. 2. Place the return air cover up to the ceiling tem- plate. 3. Install cover to template using six (6) supplied #8 x 10 mm blunt point Phillips head screws.
For a more permanent solution to high heat gain, acces- sories like Dometic outdoor patio and window awnings will reduce heat gain by removing the direct sun. They also add a nice area to enjoy company during the cool of the evening.
Need help?