Model | APH320 |
CADR | 188 CFM (320 m²/h) |
Power Supply | AC 120 V |
Standby Power | 2 W |
Rated Power | 77 W |
Dust Sensor | Laser PM2.5 Particle Sensor |
Filter Structure | Pre-Filter, H13 Class True HEPA Filter, Activated Carbon Filter |
UV Light | UV-C LED |
Wavelength | 270-275 nm |
Bulb life | Approx. 50,000 hours |
Noise Level | 22-46 dB |
OZONE DENSITY about HEPA AIR PURIFIER
This product complies with the maximum allowable concentration of ozone of 0.050 parts per million by volume (ppmv) in a 24-hour period.
The Health Canada Guideline 2010 recommends that the maximum exposure limit, based on an averaging time of 8 hours, is 0.020 ppmv or less when tested in a sealed, controlled room approximately 30 m³.
Follow these instructions to reduce the risk of serious injury or death and to reduce risk of damaging the unit.
Please make sure the operating voltage is the same as parametric label.
For American and Canadian users, our product will equipped with a POLARIZED AC PLUG that will fit into the power outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If it still does not fit, contact qualified personnel to install the proper outlet.
Power Button
PM2.5 ( µg/m3) | Levels of Health Concern | AQI (EPA of USA) | Fan Speed |
0.0-12.0 | Good | 0-50 | Low |
12.1-35.4 | Moderate | 51-100 | Medium |
35.5-150 | Unhealthy | 101-200 | High |
Instant PM2.5 value is one of the core references for indoor air quality index (AQI).
Regarding the AQI, working modes, and lights indicators, Airthereal APH320 Air Purifiers comply with EPA regulations.
For additional Information, please reference the United States Environmental Protection Agency (EPA): https://cfpub.epa.gov/airnow/index.cfm?action=aqi_brochure.index#particle
Fan Speed
Press to start air circulation. 3 fan speeds are available (low, medium, and high, corresponding with the values 1, 2, and 3 on the LED Display).
Each press will cycle between Auto→1→2→3→then start over with Auto.
WiFi
After the unit is powered on, please press and hold the POWER and FAN buttons simultaneously for 3 seconds to enter the connection mode. The WiFi icon will flash white, indicating that the unit is ready to connect. Once you have set up the connection, the WiFi icon will stop flashing and become illuminated in white.
Anion
Press to activate/inactivate the Anion Mode.
When the anion function is on, it becomes an air ionizer that uses high voltage to ionize air molecules.
Anions are particles with one or more extra electron, conferring a net negative charge to the particle. It's used to eliminate the occurrence of airborne bacterial infections and to reduce static electricity buildup.
Timer
Press to switch to timer mode. (Timer can be set from 1-12 hours or to NO TIMER, corresponding to values 1-12 and 00 on the LED display.)
Sleep Mode
Press to turn on / off the Sleep Mode.
NOTE:
Child-Lock
Press and hold the Child-Lock button for 5 seconds to Lock and unlock.
UV-C Light
Press to activate/inactivate the UV-C Light mode.
UV-C refers to ultraviolet light with wavelengths between 200 - 280 nanometers (nm). It can be used for destroying harmful micro-organisms in food products and in the air.
Airthereal Pure Morning APH320 Air Purifier has passed ETL's stringent testing requirements. The UV-C light is rated at 50,000 hours, or slightly longer than 5 years. There's no need to replace the UV light under normal operating conditions.
When the PM2.5 indicator light flashes red, it is a reminder to check and change the air filter.
We recommend replacing the air filter every 6-8 months for optimal use.
It's time to replace the air filter when below signals appear:
Purchase a new Airthereal Air Filter Replacement:
Visit: www.airthereal.com
Search on Amazon: APH320 air purifier replacement filter / B089K1TMWS
Only use Airthereal Pure Morning APH320 replacement filters for this unit.
Replace the Air Filter
Unplug the power cord before cleaning.
The plastic shell should be cleaned with a soft, damp cloth. Add mild detergent as needed.
Remove the front panel and clean both sides of the air outlet with a vacuum cleaner to remove any dust.
For optimal maintenance, clean the unit every 2 months
Problem | Cause | Solution |
No power or response | Unit is not plugged into an electrical outlet. | Connect the plug to a powered electrical outlet. |
Outlet is not working properly. | Try plugging the air purifier into a different outlet. | |
Front cover is not properly placed on the unit. | Properly replace the front cover as noted in the Getting Started section. | |
Power cord is damaged. | Immediately discontinue use and contact Customer Support. | |
Air purifier is defective or malfunctioning. | ||
Any faulty display of the LED numbers | Auto Mode has just been turned on. | Allow the air purifier to run for 30S. They will change a stabilized status based on the detected air quality |
Unit is defective or malfunctioning. | Immediately discontinue use and contact Customer Support. | |
Unusual noise while operating | Dirty filters. | Replace the air filters as instructed in the Replacing the Air Filters section. |
Filters installed improperly. | Properly place filter as noted in the Getting Started and Replacing the Air Filters sections. | |
Foreign object inside the unit. | Immediately discontinue use and contact Customer Support. DO NOT attempt to open the air purifier. | |
Flimsy or slanted surfaces resulting in abnormal noise and vibrations. | Place air purifier on hard, flat surfaces. | |
Significantly reduced airflow | Not enough space around the unit. | Ensure that there is at least 15 inches (38 cm) between the unit and other objects. |
Poor air purification quality | Surrounding area exceeds the applicable area. | APH320 is applicable to 435 ft² (40 m²). |
Air inlet or outlet is blocked. | Remove objects that block the air inlet or outlet. | |
Filter(s) not properly placed in housing. | Properly place filter as noted in the Getting Started and Replacing the Filters sections. |
Please read and comply with all of the instructions and warnings in the manual before using. Failure to comply with the instructions and warnings provided herein may result in inaccurate results and/or damage to the product itself.
Only use this air purifier as described in this manual.
How to request warranty services?
To obtain the benefit of this warranty, please leave a message online (https://airthereal.com/pages/warranty), or send an email to support@airthereal.com. Our customer service will get back to you within 24 hours.
Always here to help you
www.airthereal.com
Keep Out Of Reach Of Children
Produced for: West Ryder Technology LLC
251 Little Falls Drive, Wilmington, DE 19808-1674, USA
EPA EST NO: 99066-CHN-1
support@airthereal.com
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Airthereal Pure Morning APH320 - HEPA AIR PURIFIER Manual
Advertisement
Need help?
Do you have a question about the Pure Morning APH320 and is the answer not in the manual?
Questions and answers