Universal Controller
Two-Way Siren Controller
Models: UCT-WLN Series
Description, Specifications, Installation,
Operation, and Service Manual
25500901
Rev. A0 0224
Printed in U.S.A.
© Copyright 2024 Federal Signal Corporation

Advertisement

Table of Contents
loading

Summary of Contents for Federal Signal Corporation UCT-WLN Series

  • Page 1 Universal Controller Two-Way Siren Controller Models: UCT-WLN Series Description, Specifications, Installation, Operation, and Service Manual 25500901 Rev. A0 0224 Printed in U.S.A. © Copyright 2024 Federal Signal Corporation...
  • Page 2 A copy of this limited warranty can also be obtained by written request to Federal Signal Corporation, 2645 Federal Signal Drive, University Park, IL 60484, email to info@fedsig.com or call +1 708-534-3400.
  • Page 3: Table Of Contents

    Contents Safety Messages..............................6 General Description ..............................9 Overview ................................9 Features ................................9 Ordering Products ..............................10 Parts List ................................11 Specifications ................................12 UCT-WLN Control Cabinet Specifications ......................12 Control Board Specifications ..........................12 DC-DC Converter (2005173) Board Specifications ..................13 UCT-WLN Interface PCB (20000628) Specifications ..................14 Installation ................................14 Electrical Code Compliance ..........................15 Preliminary ................................15...
  • Page 4 Table 13 Concrete or Filled Cement Block Wall Mounting Materials ..............18 Table 14 Hollow Block Wall Mounting Materials ....................19 Table 15 Wood Stud Wall Mounting Materials ....................19 Table 16 Metal Stud Wall Mounting Materials .....................20 Table 17 Recommended Equipment ........................21 Universal Controller (Models UCT-WLN Series) Federal Signal www.fedsig.com...
  • Page 5 Table 18 FC Controller Board Indicators ......................28 Table 19 Configuration Jumpers on the Control Board ..................29 Table 20 Switches ..............................32 Table 21 Speaker Output ............................32 Table 22 Radio Adjustment ...........................33 Table 23 Jacks ...............................35 Table 24 Squelch Controls ...........................35 Figures Figure 1 Parts List ..............................
  • Page 6: Safety Messages

    Activating the sirens may not result in people taking the desired actions if those to be warned are not properly trained about the meaning of siren sounds. Siren users should follow FEMA recommendations and instruct those to be warned of corrective actions to be taken. Universal Controller (Models UCT-WLN Series) Federal Signal www.fedsig.com...
  • Page 7 Safety Messages • After installation, service, or maintenance, test the siren system to confirm that it is operating properly. Test the system regularly to confirm that it will be operational in an emergency. • If future service and operating personnel do not have these instructions to refer to, the siren system may not provide the intended audible warning, and service personnel may be exposed to death, permanent hearing loss, or other bodily injuries.
  • Page 8 NOTICE is used to address practices not related to physical injury. Read and understand the information contained in this manual before attempting to deploy or service the siren. Pay careful attention to notices located on the equipment. Universal Controller (Models UCT-WLN Series) Federal Signal www.fedsig.com...
  • Page 9: General Description

    General Description General Description Overview The Universal Controller (UCT-WLN) series of siren controllers allow third-party devices and sirens from other manufacturers to be controlled and monitored from Federal Signal SS2000+, Commander , CommanderOne , and CommanderOne-LE siren control ® ® products.
  • Page 10: Ordering Products

    Omni directional antenna (VHF, UHF, and 800 MHz models available) YAGI-xx Directional antenna (VHF, UHF, and 800 MHz models available) CELL-ANT1 4G cellular 9 dB gain antenna NOTE: Standard antenna connections are Type N. Universal Controller (Models UCT-WLN Series) Federal Signal www.fedsig.com...
  • Page 11: Parts List

    Parts List Parts List The following figure and table lists the parts included. If you are missing any parts, contact Customer Support. See “Getting Technical Support and Service” on page 36. Figure 1 Parts List DC Power Wires (17503007A) Data Cable (175783A-14) NEMA 4 Cabinet PA Audio Cable...
  • Page 12: Specifications

    Space between Stacked codes 50 ms/50 ms mark/space timing minimum 1.25 seconds NOTE: Wildcard options for each of the DTMF strings via programming software. Optional fast DTMF 40 ms/20 ms with jumper JP29 shorted. Universal Controller (Models UCT-WLN Series) Federal Signal www.fedsig.com...
  • Page 13: Dc-Dc Converter (2005173) Board Specifications

    Specifications Baud rate 1200 bps Modem type MSK (minimal shift key) Mark frequency 1200 Hz Space frequency 1800 Hz Error checking 16 bit CRC Table 8 Inputs and Outputs Relay Outputs Four relay outputs Normally Open or Normally Closed Contact Rating 8 A at 120/240 Vac 5 A at 24 Vdc Audio Output (Optional)
  • Page 14: Uct-Wln Interface Pcb (20000628) Specifications

    PROPERTY DAMAGE: Federal Signal recommends padlocking all control devices to discourage tampering and vandalism. STATIC-SENSITIVE DEVICE When servicing the board, avoid Electrostatic discharge by properly grounding yourself and the board. Universal Controller (Models UCT-WLN Series) Federal Signal www.fedsig.com...
  • Page 15: Electrical Code Compliance

    Installation Electrical Code Compliance This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: • This device may not cause harmful interference. • This device must accept any interference received, including interference that may cause undesired operation.
  • Page 16: Figure 2 Compatible Control Logic Boards

    Installation The UCT-WLN series siren controllers are designed to be compatible with the Whelen ® model 2020 or 2023 Control Logic boards manufactured after 2001. The two types of compatible control boards are shown below. Verify that the existing siren controller has one of the two compatible boards before installing the new UCT-WLN controller.
  • Page 17: General Mounting Guidelines

    Installation The UCT-WLN cabinet has four 5/16-inch mounting holes located on both the top and bottom mounting flanges that can be used to mount to a wall or other horizontal structure. Two pole mounting brackets are provided for pole mount installations. Two 1/2-inch conduit fitting holes are provided for conduit connections on the bottom of the UCT-WLN cabinet.
  • Page 18: Installation Material List And Installation Guidelines

    Install the anchor bolts for the four cabinet corners according to the manufacturer’s instructions. Mount the cabinet to the wall. Proceed to the following section. NOTE: If the wall is not straight, use shims to ensure the enclosure maintains square and structural integrity. Universal Controller (Models UCT-WLN Series) Federal Signal www.fedsig.com...
  • Page 19: Hollow Block Wall Mounting Guidelines

    Installation Hollow Block Wall Mounting Guidelines Table 14 Hollow Block Wall Mounting Materials Material Description Purpose 1/4 in x 2 in Heavy Duty Toggle Bolts Anchor Bolts To mount the cabinet on a hollow block wall: Mark the mounting hole locations on the wall for the cabinet. Install the anchor bolts for the four cabinet corners according to the manufacturer’s instructions.
  • Page 20: Metal Stud Wall Mounting Guidelines

    Qualifications You must be a properly trained technician or electrician to install this product. Universal Controller (Models UCT-WLN Series) Federal Signal www.fedsig.com...
  • Page 21: Recommended Equipment

    Installation Recommended Equipment Federal Signal recommends having the following installer-supplied equipment. Table 17 Recommended Equipment Check Material Description Purpose 1/2-inch seal-tight conduit and Electrical conduit from UCT-WLN to siren fittings control cabinet. Metal ground connectors Equipment ground connections Ground lead Solid 6 AWG from UCT-WLN lightning arrestor to earth ground Screws/bolts/banding or...
  • Page 22: Figure 5 Original Equipment Locations

    Disconnect the Radio Antenna Cable Connection. Keep the mounting screws and discard the Radio Interface Board Assembly and the Radio Interface Wireset. Figure 5 Original Equipment Locations Radio Antenna Radio Interface Cable Connection Wireset Radio Interface Board Assembly Control Board Mounting Bracket Universal Controller (Models UCT-WLN Series) Federal Signal www.fedsig.com...
  • Page 23: Figure 6 New Equipment Locations

    Installation 5. Mount the UCT-WLN Interface PCB (20000628) at the Radio Interface Board Assembly location using the screws removed from the radio interface board. (See Figure 6.) 6. Install the Data Cable (175783A-14) and PA Audio cable (if PA over radio will be used). Leave some slack and wire tie the new cables to the existing wire loom as shown in Figure 6.
  • Page 24: Figure 7 Wiring

    Connect the black 14 AWG wire to the black 14 AWG wire with the female barrel connector. 12. Bundle and tie wrap the excess length of cable in the siren control cabinet. Universal Controller (Models UCT-WLN Series) Federal Signal www.fedsig.com...
  • Page 25: Figure 8 Uct-Wln Wiring Diagram

    Installation Figure 8 UCT-WLN Wiring Diagram Description, Specifications, Installation, Operation, and Service Manual Federal Signal www.fedsig.com...
  • Page 26: Installing The Antenna

    Elevation and distance changes of a few hundred feet can often make a significant difference in signal strength. • Connect the antenna or antenna cable to the N bulkhead connector. Universal Controller (Models UCT-WLN Series) Federal Signal www.fedsig.com...
  • Page 27 Installation • Mount the antenna on the side of the pole facing the base station location. Mount as high as possible. When possible, the tip of the antenna should be no closer than three feet from any metal siren mounting brackets. NOTE: For installation instructions on the Yagi and Omni Antennas, go to the Federal Signal’s website.
  • Page 28: Operations

    AC Power Fail Sensor (internal) POWER LED 12 V Operating Power ISO 12V Isolated 12 V power ISO 5V Isolated 5 V power LCD Display Displays Function Counters, Decodes, and Software Revision Universal Controller (Models UCT-WLN Series) Federal Signal www.fedsig.com...
  • Page 29: Connectors, Selections, And Switches For The Uct-Wln Controller Board

    Operations Connectors, Selections, and Switches for the UCT-WLN Controller Board The following tables provide descriptions of the UCT-WLN controller board connectors, selections, and switches. Table 19 Configuration Jumpers on the Control Board Future Use Test Speaker/Audio Out (See R76 for output level adjustment) 0 to 3 V Audio Source: Receiver Audio during PA functions Siren Audio during Electronic Siren functions...
  • Page 30 When JP9 is shorted, the LED lights on the board turn off when the door is closed to reduce the current draw. Uses less power for Solar powered systems. Intrusion switch is only present on two-way systems. Universal Controller (Models UCT-WLN Series) Federal Signal www.fedsig.com...
  • Page 31 Operations JP10 Remote Activation and Sensor Inputs (#1 at left edge of connector) Spare Sensor Input #2, dry Contact closure < 1 K NOTE: Typically used for transformer rectifier or AC sensor. ISO Ground Spare Sensor Input #1, dry Contact closure < 1 K NOTE: Typically used for rotation sensor.
  • Page 32: Switches

    You can adjust speaker output up to 2.0 V into an 8-ohm load using R76. Table 21 Speaker Output Test Speaker output level set Universal Controller (Models UCT-WLN Series) Federal Signal www.fedsig.com...
  • Page 33: Radio Adjustment

    Operations Radio Adjustment If a two-way radio is connected to the Transceiver Interface Connector P1, radio deviation level adjustments must be completed using the potentiometers listed below. For the radio deviation level adjustment procedure, see the DCUCT-WLNTB manual. Table 22 Radio Adjustment External transceiver receive audio set to 1 V at TP6 MSK modem transmit deviation level set...
  • Page 34: Figure 9 Setting The Switch Number Example

    (battery and AC). • For DTMF, Two Tone Sequential Systems, and MOSCAD only: The unit address is defined in the programming; therefore, all DIP switches shall be positioned all to the right. Universal Controller (Models UCT-WLN Series) Federal Signal www.fedsig.com...
  • Page 35: Connectors And Jacks For Optional Rf Receiver

    Operations Connectors and Jacks for optional RF Receiver For the UCT-WLN and UCT-WLNU units. Table 23 Jacks Shield ground Center antenna RF Input Radio to UCT-WLN controller connector Table 24 Squelch Controls Squelch control The squelch control adjusts the squelch threshold level. Programming Turn the siren controller battery disconnect switch on and apply AC power to the Whelen ®...
  • Page 36: Maintenance

    For technical support, contact: Federal Signal Technical Support Phone: 800-524-3021 or 708-534-4790 Email: techsupport@fedsig.com www.fedsig.com For customer support, contact: Federal Signal Customer Support Phone: 800-548-7229 or 708-534-3400 extension 367511 Email: customersupport@fedsig.com www.fedsig.com Universal Controller (Models UCT-WLN Series) Federal Signal www.fedsig.com...