Download Print this page
Federal Signal Corporation SIGNALMASTER 331102 Instruction Sheet
Federal Signal Corporation SIGNALMASTER 331102 Instruction Sheet

Federal Signal Corporation SIGNALMASTER 331102 Instruction Sheet

Advertisement

Quick Links

2561007E
REV. E 1002
Printed in U.S.A.
SAFETY MESSAGE TO INSTALLERS
People's lives depend on your safe installation of our products.
It is important to read, understand and follow all instructions
shipped with the products. In addition, listed below are some other
important safety instructions and precautions you should follow:
To properly install this light: you must have a good
understanding of automotive electrical procedures
and systems, along with proficiency in the installa-
tion and use of safety warning equipment.
DO NOT install equipment or route wiring in the
deployment path of an air bag.
When drilling into a vehicle structure, be sure that
both sides of the surface are clear of anything that
could be damaged.
In order for the light to function properly, a good
ground connection must be made. At a minimum, it
must be attached to a solid metal body or chassis
part that will provide an effective ground path as
long as the light system is to be used.
Locate light control so the VEHICLE and CON-
TROL can be operated safely under all driving
conditions.
Do not attempt to activate or deactivate light control
while driving in a hazardous situation.
This product controls high intensity LED devices. To
prevent eye damage, DO NOT stare into the light
beam at close range.
You should frequently inspect the light to ensure
that it is operating properly and that it is securely
attached to the vehicle.
File these instructions in a safe place and refer to
them when maintaining and/or reinstalling the
product.
Failure to follow all safety precautions and instructions may
result in property damage, serious injury, or death to you or
others.
I.
GENERAL.
The Federal Signal SignalMaster Model 331102 is an
economical, low profile, solid state, directional light control that is
designed to operate with any of Federal Signal's SignalMaster
series eight-lamp directional lights. This control will also operate
two sets of external lamps (Federal Signal Models 320102,
SMLED1, 320112, and 320721, or other 50 watt lamps). The unit
is reversed polarity protected to avoid damage if the positive and
negative power connections are connected incorrectly.
This model provides three distinctive directional signals, left
arrow, right arrow, and center out. An alternating flash pattern
produces a warning signal for use when a directional signal may
not be appropriate. In addition, an auxiliary flash pattern
alternately flashes the external lamps. The directional and
alternating flash patterns can also be selected to operate faster, or
with decreased current draw. The slide switch overrides the
WARN and AUX functions.
When normal directional signal operation is selected, the
lamps individually activate sequentially in a sweeping motion
until all eight are illuminated. When LOW (current) operation is
selected, the lamps turn on/off in sequence until a pattern is
completed. When FAST is selected, the chosen pattern sequences
at an increased rate.
INSTRUCTION SHEET
FOR
SIGNALMASTER™ MODEL 331102
external controls and lights into the SignalMaster system. When
properly connected, a positive (+) 12 volts applied to the AUX IN
terminal will activate the alternating flash pattern. The AUX OUT
terminal can activate a ground-activated relay (user-supplied)
when the AUX switch is operated.
II.
Input Voltage
Polarity
Operating Temperature
Range
Standby Current
+BAT Fuse
+IGNITION Fuse
AUX OUT Fuse
Output Drive
Capability (Total)
Normal Flash Rate:
Fast Flash Rate:
Dimensions:
III.
tions packed with the 320340 universal mounting kit. Route the
cable near the eventual location of the control unit.
An auxiliary input and output are provided for integrating
WARNING
These lights are intended for secondary warning only.
They are not intended for use as a primary warning
system.
SPECIFICATIONS.
11VDC to 16VDC.
Negative ground only.
-30° C to +65° C.
Zero amperes.
25 amperes.
1 ampere.
1 ampere.
Directional
8, 27 watt lamps.
Auxiliary
4, 27 watt lamps (2 per output) or
2, 50 watt lamps (1 per output).
Directional
35 patterns/min.
Warn
60 patterns/min.
Auxiliary
95 patterns/min.
Directional
60 patterns/min.
Warn
95 patterns/min.
Auxiliary
95 patterns/min.
Height
1-1/2"
Width
6-1/8"
Depth
5"
Shipping Weight
2.5 lbs.
INSTALLATION.
A.
SignalMaster Light Assembly.
Install the light assembly as described in the instruc-
B.
Control Unit.
WARNING
When installing equipment inside air bag equipped ve-
hicles, the installer MUST ensure that the equipment is
installed ONLY in areas recommended by the vehicle
manufacturer.
Failure to observe this warning will reduce the effective-
ness of the air bag, damage the air bag, or potentially
damage or dislodge the equipment, causing serious injury
or death to you or others.

Advertisement

loading

Summary of Contents for Federal Signal Corporation SIGNALMASTER 331102

  • Page 1 2561007E REV. E 1002 Printed in U.S.A. INSTRUCTION SHEET SIGNALMASTER™ MODEL 331102 An auxiliary input and output are provided for integrating SAFETY MESSAGE TO INSTALLERS external controls and lights into the SignalMaster system. When People’s lives depend on your safe installation of our products. properly connected, a positive (+) 12 volts applied to the AUX IN It is important to read, understand and follow all instructions terminal will activate the alternating flash pattern.
  • Page 2 See figure 1. The supplied mounting bracket allows the WARNING control unit to be mounted in a variety of positions. To install the Do not connect more than one, 6 or 8 head, halogen control unit, proceed as follows: SignalMaster assembly to a SignalMaster control- ler or the SignalMaster outputs of a SmartSiren.
  • Page 3 Connect the remaining SignalMaster wires to WIRE STRIPPING the eleven-position connector as shown in figures 2 and 3. TYPICAL If applicable, connect the external lamp ground cables to the connector (positions 9 and 10) as shown in figures 2 and 3. Each of these two positions provides an alternating ground signal to activate external lamps.
  • Page 4 If this switch is operated while the WARN pattern is activated, the first and eighth lamp activate alternately with the SignalMaster FEDERAL SIGNAL CORPORATION third and sixth lamp. The selection of this function reduces the current draw for the directional light assembly’s patterns. The...