iii) Press F12 to return to the SST main menu.
e) On the System Service Tools (SST) display, select Work with disk units > Work with disk
configuration > Work with NVM Devices > Create NVM Namespaces.
f) Select the NVMe device that you installed.
g) On the Create NVM Namespaces display, select the quantity and capacity of the namespaces
(disk units) that you want to create on the newly installed NVMe device.
h) Press F10 to confirm the creation of the namespaces.
i) Press F12 to return to the SST main menu.
16. Continue with step "18" on page 15.
17. If you are using the Linux operating system, complete the following steps:
a) In the Linux session on the console, press Enter after you install or replace the adapter to put the
slot into the action state.
b) Enter the slot information with the lsslot command, as shown in the following example.
For example, if the slot in which you installed the adapter was U7879.001.DQD014E-P1-C3.
Enter lsslot -c pci -s U7879.001.DQD014E-P1-C3
The following screen is an example of the information that is displayed by this command:
# Slot
U7879.001.DQD014E-P1-C3 PCI-X capable, 64 bit, 133MHz slot 0001:40:01.0
18. Verify the installed part.
• If you replaced the part because of a service action, verify the installed part. For
instructions, see Verifying a repair (www.ibm.com/support/knowledgecenter/POWER10/p10ect/
pxect_verifyrepair.htm).
• If you installed the part for any other reason, verify the installed part. For instructions,
see Verifying the installed part (www.ibm.com/support/knowledgecenter/POWER10/p10haj/
pxhaj_hsmverify.htm).
19. Turn off the identify LED. For instructions, see Deactivating an identify LED (www.ibm.com/support/
knowledgecenter/POWER10/p10haj/p10haj_turn_off_identify_led.htm).

Related procedures for installing adapters

Find procedures that are related to installing adapters.
Updating the worldwide port name for a new 5735 IOA
If you exchange a 5735 Fibre Channel input/output adapter (IOA), the IBM external storage subsystem
must be updated to use the worldwide port name (WWPN) of the new 5735 IOA. Any SAN hardware that
uses the WWPN zoning might also need updating.
For instructions on how to update the external storage subsystem or SAN hardware configurations, see
the documentation for those systems.
The WWPN for the Fibre Channel IOA can be found by using the Hardware Service Manager in SST or DST
to display details about the 5735 IOA Logical Hardware Resource information, and use the port worldwide
name field.
The 16-digit WWPN can also be determined by appending the digits 1000 to the beginning of the 12-digit