Smeg PGF31G Manual page 18

Table of Contents

Advertisement

8.2
Burner and nozzle characteristics table
Burner
Auxiliary (1)
Rapid (2)
Dual crown (3) INT
Dual crown (3) EXT
Burner
Auxiliary (1)
Rapid (2)
Dual crown (3) INT
Dual crown (3) EXT
8.3
Arrangement of the burners on the cooking hob
After making the adjustments described above, reassemble the appliance by
following the instructions in point "8.1 Replacement of nozzles on the hob" in
reverse order.
After adjustment with a gas other than the preset one, replace the label on the
bottom of the casing with the label corresponding to the new gas. This label is
supplied with the appliance (when applicable) or can be obtained from the
nearest Authorised Service Centre.
40
Instructions for the installer
Rated heating
capacity
(kW)
Nozzle
diameter
1/100 mm
1.05
2.50
0.90
3.60
68 + 68
Rated heating
capacity
(kW)
1.05
2.50
0.90
3.60
2
1
Liquid gas - G30/G31 28/37 mbar
By-pass
mm
1/100
50
30
79
42
46
30
63
Natural gas - G20 20 mbar
Nozzle diameter
1/100 mm
72
108
70
102 + 102
1 Auxiliary
3
2 Rapid
3 Dual crown
Rated
Rated
capacity
g/h G30
(W)
400
76
800
182
400
65
1600
262
Reduced capacity
(W)
400
800
400
1600
HOB BURNER
Rated
g/h G31
75
179
64
257
I

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pgf32g

Table of Contents