10.6 Adjusting the minimum setting for LPG
To adjust the minimum setting with LPG, you must tighten the screw inside or
next to the tap rod (depending on the model) fully in a clockwise direction.
The diameters of the by-passes for the individual burners are given in the table
"10.3 Burner and nozzle characteristics tables".
After adjustment with a gas other than the preset one, replace the label on the
casing of the appliance with the label corresponding to the new gas. The label is
inserted inside the pack together with the nozzles.
10.7 Arrangement of the burners on the hob
10.8 Lubrication of gas taps
Over time the gas taps may become difficult to turn and get blocked. Clean them
internally and replace the lubrication grease.
This procedure must be carried out by a specialised technician.