Flow Control Eductor Nozzle
Listed below is the recommended eductor nozzle to be used at various salt dosages.
Tank
Injector
10 x 54
1 - white
12 x 52
1 - white
14 x 65
4 - green
16 x 65
4 - green
Refer to Figure 6 for a visual on changing the eductor nozzle and the backwash flow control.
Drain Elbow
Flow Control
Drain Clip
Injector Clip
Eductor Nozzle Replacement:
•
Remove the injector clip on the eductor cap and remove the cap.
•
Remove the injector assembly.
•
Remove the injector screen from the assembly
•
Remove the injector assembly that is shipped inside the control and replace it with the proper
assembly as per Table 2.
•
Reverse the procedure to reassemble.
Draw Rate
DLFC (gpm)
0.38
0.38
0.78
0.78
Table 2 - Flow Restrictors
Injector Cover
Injector Assembly
Injector Screen
Brine Clip
Brine Fitting
Tube Ferrule
Brine Fitting Nut
Figure 6
BLFC (gpm)
2
0.25
3.5
0.25
5.0
0.50
6
0.50
Tube Insert
Installation
(cont.)
13