Summary of Contents for Thermo King TriPac Envidia 2
Page 1
Operator’s Manual TriPac® ® Envidia™ ™ 2 Revision B T T K K 5 5 7 7 2 2 5 5 0 0 - - 1 1 9 9 - - O O P P - - E E N N March 2024...
Page 2
If more information is required, consult your Thermo King Service Directory for the location and telephone number of the local dealer. T T h h e e r r m m o o K K i i n n g g ’ ’ s s w w a a r r r r a a n n t t y y s s h h a a l l l l n n o o t t a a p p p p l l y y t t o o a a n n y y e e q q u u i i p p m m e e n n t t w w h h i i c c h h h h a a s s b b e e e e n n “...
I I n n t t r r o o d d u u c c t t i i o o n n Software License The product includes software that is licensed under a non-exclusive, non- sub-licensable, terminable and limited license to use the software as installed on the product for its intended purpose.
M M a a n n u u a a l l P P r r e e - - T T r r i i p p I I n n s s p p e e c c t t i i o o n n ..............2 2 3 3 Before Starting the TriPac Envidia 2 Unit..... 23...
Page 5
T T a a b b l l e e o o f f C C o o n n t t e e n n t t s s O O p p e e r r a a t t i i n n g g I I n n s s t t r r u u c c t t i i o o n n s s ................2 2 4 4 HMI Control Panel Operation .
Page 6
T T a a b b l l e e o o f f C C o o n n t t e e n n t t s s Engine Oil Change Intervals......40 Electrical .
Safety Danger, Warning, Caution, and Notice Thermo King® recommends that all service be performed by a Thermo King dealer and to be aware of several general safety practices. Safety advisories appear throughout this manual as required. Your personal safety and the proper operation of this unit depend upon the strict observance of these precautions.
Page 8
E E q q u u i i p p m m e e n n t t D D a a m m a a g g e e ! ! Do not connect other manufacturers’ equipment or accessories to the unit or to the Thermo King batteries unless approved by Thermo King. Failure to do so can result in severe damage to equipment and void the warranty.
S S a a f f e e t t y y N N o o t t i i c c e e E E q q u u i i p p m m e e n n t t D D a a m m a a g g e e ! ! Some appliances or electronic devices may not operate properly when powered through a DC to AC power inverter.
S S a a f f e e t t y y D D a a n n g g e e r r R R e e f f r r i i g g e e r r a a n n t t V V a a p p o o r r H H a a z z a a r r d d ! ! Do not inhale refrigerant.
Page 12
S S a a f f e e t t y y R R E E F F R R I I G G E E R R A A N N T T O O I I L L •...
Move victim to fresh air and use Cardio Pulmonary Resuscitation (CPR) or mouth-to-mouth resuscitation to restore breathing, if necessary. Stay with victim until emergency personnel arrive. Safety Nameplates Figure 1. Typical TriPac Envidia 2 Safety Nameplates Shown. WARNING • EXPLOSION AND FIRE HAZARD FROM ELECTRIC HVAC AND IN-CAB HEATER SPARKS •...
Page 14
Optional Shore Power Converter provides the capability of running the TriPac Envidia 2 system or charging the batteries if 115 Vac 15 Amp electrical power is available. N N o o t t e e : : The system is designed for overnight driver comfort. Several hours of drive time are needed to charge the TriPac Envidia 2 batteries before the next TriPac operation.
Optional Shore Power converter to keep the tractor batteries fully charged and extend Hotel Load capacity. Suggestions to Maximize Run Time Maximum climate control time is controlled by the total available power reserve in the TriPac Envidia 2 and truck batteries. To achieve maximum run TK 57250-19-OP-EN...
• 1000 Watt Inverter (Optional) Battery Box Thermo King recommends that the tractor’s batteries also be of the same type as the TriPac Envidia batteries for optimum performance and battery life. N N o o t t i i c c e e E E q q u u i i p p m m e e n n t t D D a a m m a a g g e e ! ! Do not use the TriPac batteries to jump start a vehicle.
Thermo King recommends that the tractor’s batteries also be of the same type as the TriPac Envidia 2 batteries for optimum performance and battery life. Figure 2. TriPac Envidia 2 Battery Box...
U U n n i i t t D D e e s s c c r r i i p p t t i i o o n n Figure 3. Evaporator/Control Box Shown Condenser and Receiver Drier The air conditioning condenser is mounted on the back of the truck cab. It contains a variable speed fan.
Heater (Optional) The optional fuel-fired air heater is typically installed in the cargo compartment under the truck cab sleeper compartment. It draws fuel from the truck’s diesel fuel tank and electric power from the TriPac Envidia 2 batteries. Figure 6. Heater...
Shorter system runtime will be experienced without the battery upgrade. N N o o t t e e : : The TriPac Envidia 2 system uses the energy from truck batteries as a power reserve for system operation. Verify that this application is accepted by the truck OEM.
U U n n i i t t D D e e s s c c r r i i p p t t i i o o n n Protection Devices Air Conditioning System The Evaporator/Control box contains sensors that protect the Air Conditioning system.
Perform this pre-trip inspection before every trip. I I m m p p o o r r t t a a n n t t : : Contact your nearest Thermo King Dealer immediately if problems are found.
Operating Instructions HMI Control Panel Operation The TriPac Envidia 2 is operated using an HMI (Human Machine Interface) Control Panel which is typically mounted on a wall in the truck cab sleeper compartment. Figure 7. HMI Control Panel RCS1646 HMI Control Panel Display The HMI is an easy to use control that allows the driver to select the desired function of the system.
O O p p e e r r a a t t i i n n g g I I n n s s t t r r u u c c t t i i o o n n s s D D a a n n g g e e r r R R i i s s k k o o f f I I n n j j u u r r y y ! ! Always turn the unit off while refueling the truck.
By default, it considers four truck batteries in the system. Green bars will scroll up while truck ignition is on. This indicates the TriPac Envidia 2system is in the Charge Mode. It does not indicate the TriPac Envidia 2 batteries are charging.
• Yellow = Check Alarm. This type of alarm indicates the system has an abnormal condition that should be checked by a Thermo King technician at the next opportunity. The system will continue to operate but may have reduced capacity.
Bump three more times. I I m m p p o o r r t t a a n n t t : : If system alarms continue to appear, contact an authorized Thermo King Dealer. Figure 13.
Truck Running Charging amperage is provided by the truck alternator. A 270 amp alternator is the minimum required to support the TriPac Envidia 2 system. For many applications or truck operation profiles, such as high tractor duty load, high driver hotel load, extended layover duration, high ambient temperature or short drive times between layovers, increased battery charging capacity may be required.
TriPac Envidia 2 HVAC load. N N o o t t e e : : The Shore Power Converter should not be connected if the truck is running.
Page 33
O O p p e e r r a a t t i i n n g g I I n n s s t t r r u u c c t t i i o o n n s s RCS1651 Maximum Battery Discharge = Less Run Time Minimum Battery Discharge = More Run Time...
Page 34
TriPac Envidia system will shut down. N N o o t t e e : : Thermo King recommends that 800 watt or smaller microwave ovens be used with the optional TriPac Envidia power inverter.
Control System 12 Vdc Voltage APU Battery Box: Four Thermo King NXT, AGM, Deep Cycle Truck Battery Box: Four, Group 31, 1150 CCA Minimum, (Thermo King Batteries NXT Recommended) Truck mounted, 12 V, 270 amp minimum required (300 amp Alternator...
S S p p e e c c i i f f i i c c a a t t i i o o n n s s Fuse Location Component Protected/ Num- Rat- Circuit - Connector Fuse Block in Battery Box APU Battery Top Right Fuse Block in Battery Box APU Battery Bottom Right...
S S p p e e c c i i f f i i c c a a t t i i o o n n s s Figure 17. Fuses Inside Base Controller Optional AC to DC Power Converter Extension Cord Size: Length Up to 75 ft.
Air Conditioning System The TriPac Envidia 2 air conditioning system must be serviced by an authorized Thermo King Dealer. Optional Heater The TriPac Envidia 2 diesel fuel-fired air heater must be serviced by an authorized Thermo King Dealer. TK 57250-19-OP-EN...
Thermo King dealer. N N o o t t e e : : Thermo King reserves the right to deny warranty coverage on claims due to lack of maintenance or neglect. Claims in question must be supported by maintenance records.
0 Hrs 2,000 Hour Interval -Oil change interval is every 2,000 hours of operation only when using a Thermo King brand oil filter and CK-4 or better oil. • Units with optional ATD exhaust system require CK-4 or better oil. FA-4 is not approved.
M M a a i i n n t t e e n n a a n n c c e e a a n n d d S S e e r r v v i i c c e e Electrical Thermo King recommends all electrical maintenance and service procedures be performed by an authorized Thermo King dealer.
Check condition of or service the following: • • • Visually inspect TriPac Envidia 2 battery box and condenser coil for damaged, loose or broken parts. • Check TriPac Envidia 2 battery box mounting bolts and brackets for cracks, damage and mis-alignment. Verify tightness and torque to 100 ft/lbs (135.6 N•m) for the claw mount, or 200 ft/lbs (271.2 N•m) for...
• • Inspect TriPac Envidia 2 condenser coil for debris. • Pressure wash TriPac Envidia 2 condenser coil. Do not bend coil fins or damage with air. • Blow out TriPac Envidia 2 evaporator coil and evaporator water drains with air. Do not bend coil fins or damage with air.
Page 45
TriPac Warranty Terms of the Thermo King Warranty are available on request. Please reference document TK 53051 for the Thermo King TriPac Envidia and Envidia 2 Warranty. TK 57250-19-OP-EN...
Page 46
Serial Number Locations B B a a t t t t e e r r y y B B o o x x : : Unit nameplate is located on upper right front corner of the battery box housing frame (cover must be removed to view the nameplate). E E v v a a p p o o r r a a t t o o r r / / C C o o n n t t r r o o l l B B o o x x : : Nameplate located on the side of the evaporator/ control box near the air conditioning fittings.
Page 47
Thermo King Dealer anywhere in the United States by going to thermoking. com or by using the Thermo King North American Service Directory (available from any Thermo King dealer). If you are unable to reach a dealer, then call the Toll Free Emergency Cold Line Number (888) 887-2202. The answering service will assist you in reaching a dealer to get the help you need.
Page 48
1938. For more information, visit www. thermoking.com or www.tranetechnologies.com. Thermo King has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.
Need help?
Do you have a question about the TriPac Envidia 2 and is the answer not in the manual?
Questions and answers