2.3.2 Default parameters

2.3.3 Data transmission test

After the above operation steps, follow the factory default parameters of the device and perform the following
operations to realize the transparent transmission test of data.
The operation steps are as follows:
(1) Open the test TCP/IP debugging assistant software.
(2) Select the TCP client mode (TCP Client) in the "Network Setting Area", corresponding to the remote host
address (the default local IP of the device: 192.168.3.7). The remote host port corresponds to the factory port 8887
of the device, click Connect.
(3) Wait for the computer to connect to the serial server. After the connection is completed, the LINK light of
the serial server is always on.
(4) Open the serial port assistant, select the corresponding serial port, set the baud rate to 115200, set other
serial port parameters to None/8/1, and click "Open Serial Port".
Copyright ©2012–2022,Chengdu Ebyte Electronic Technology Co.,Ltd.
Item
IP Address
Default local port
subnet mask
default gateway
Default working mode
Default destination IP
Default destination port
Serial port baud rate
Serial port parameters
default parameters
192.168.3.7
8887
255.255.255.0
192.168.3.1
TCP Server
192.168.3.3
8888
115200
None / 8 / 1