5.4 Modifiable parameters
This table lists the model choice or cycle and temperature option parameters.
F/M
ID
Description
M
P0
Appliance Type
F
P1
Appliance Model
M
P2
Boiler temperature
M
P3
Tank temperature
M
P4
Thermostop option
M
P5
Soft Start option
M
P6
Boiler temperature
offset
M
P7
Tank temperature
offset
M
P8
Real temperature
display
F
P9
Tank probe type
Note for P6 and P7: negative numbers are indicated by illumination of both decimal points (e.g.: ‐12
"1.2.")
5.5 Alarm trigger time thresholds
This table lists all the safety device trigger time thresholds.
F/
ID
Description
M
F
A0
F
A1
Boiler max. heating time
F
A2
Tank max. heating time
F
A3
Maximum water intake time
F
A4
Maximum emptying wait time
‐ CWH 510 D
CWH510D
Notes
03
Construction version
Do not modify
03
Do not modify
80C
Step 1 degree
WARNING: The actual boiler
temperature depends on whether
the connection is single‐phase or
three‐phase.
With three‐phase connection, do not
set more than 85°
58C
Step 1 degree
01
0=off 1=on
01
0=off 1=on
00
Real=measured+Offset
04
Real=measured+Offset
01
0= filtered, 1= real
01
Do not modify
Min
Default
20 min
60 min
5 min
1 min
17
Max
Notes
.
5
60
Step = 1 min
5
60
Not active with PL ON
1
20
Step = 1 min
1
2
Step = 1 min