Mechanical Specifications; Environmental Specifications - Fluke 324 User Manual

Clamp meter
Hide thumbs Also See for 324:
Table of Contents

Advertisement

323/324/325
Users Manual
Korea (KCC)
Class A Equipment (Industrial Broadcasting & Communication Equipment)
USA (FCC)
47 CFR 15 subpart B. This product is considered an exempt device per
clause 15.103.
Temperature Coefficients ........................ Add 0.1 x specified accuracy for each degree C
Resolution
323 .................................................... 0.1 A
324, 325 ............................................ (0.01, 0.1) A
Accuracy
323, 325 ............................................ 2.0 % ±5 digits (45 – 65 Hz)
324 .................................................... 1.5 % ±5 digits (45 Hz to 400 Hz)
12
Emissions that exceed the levels required by CISPR 11 can occur
when the equipment is connected to a test object.
Class A: Equipment meets requirements for industrial electromagnetic
wave equipment and the seller or user should take notice of it. This
equipment is intended for use in business environments and not to be
used in homes.
above 28 °C or below 18 °C
2.5 % ±5 digits (65 – 400 Hz)
Add 2 % for position sensitivity.