Clamp Meter
Specifications
Resistance
Range ............................................400.0 Ω/4000 Ω
Resolution ....................................0.1 Ω/1 Ω
Accuracy ......................................1 % ±5 digits
Continuity Beeper .....................≤70 Ω
Mechanical Specifications
Size (L x W x H)............................207 mm x 75 mm x 34 mm
Weight ...........................................205 g
Environmental Specifications
Temperature Coefficients.......Add 0.1 x specified accuracy for each °C above 28 °C or below 18 °C