Device Approvals - United Electric Controls VANGUARD Installation And Operation Instruction Manual

Wirelesshart toxic & combustible gas detector
Table of Contents

Advertisement

Top foam for packaging
BASE UNIT
Bottom foam for packaging
DEVICE IS SHIPPED WITHOUT THE SENSOR OR BATTERY
INSTALLED. BOTH MUST BE INSTALLED PRIOR TO USE. SEE
SECTION 2.0 INSTALLATION FOR FURTHER INFORMATION.
1.2.1 Sensors
One FLEXsense™ sensor is shipped (but uninstalled) with
the base unit (if ordered in that configuration). Additional,
spare FLEXsense™ sensors may be ordered and will ship
separately.
1.2.2 Battery
The battery pack is shipped separately from the
base unit as it contains lithium which is regulated in
transportation by the U.S. Department of Transportation,
the International Air Transport Association, International
Civil Aviation Organization, and European Ground
Transportation of Dangerous Goods.

1.3 Device Approvals

THIS DEVICE IS SUITABLE FOR HAZARDOUS LOCATIONS
PER CERTIFICATIONS (SEE BELOW) OR NON-HAZARDOUS
LOCATIONS ONLY.
THIS DEVICE MEETS ALL REQUIREMENTS FOR STANDARDS
LISTED ON THE CERTIFICATIONS (SEE BELOW).
FLEXsense™ SENSOR
Figure 3
5003390
*Ambient operating temperature range may vary with sensor type.
See datasheet for sensor specifications.
**Enclosure Type 4X and IP66 rating excludes sensor.
Special Conditions of Use:
Figure 4
Solexy RX and SX series antenna couplers must be
connected to an RF source with a minimum internal
impedance of 50 Ω.
It is considered inappropriate to provide conventional
IS parameters for this equipment. For connection to
external antenna, refer to Section 2.8 for clarification
of the antenna remote installation and Section 8 (page
18) for calculation of the RF power if supplying own
extension cable and arrestors.
The threshold power must be limited by the user in
order to achieve the levels defined in IEC/EN 60079-0
Table 5.
Equipment marked with an ambient temperature of
-40°C to +70°C/+85°C is limited to a max RF input of 2
W.
No repair/modification to the flameproof joints is
permitted
The device has been certified in accordance with the
applicable requirements of the following standards:
Each certificate lists the standard, along with standard
revision or date, which this Vanguard product meets. See
ITS-I21ATEX31360X for EN Standards.
See IECEx ETL 21.0065X for IECEx Standards. The North
America, ATEX (Europe), and IEC (International) certificates
are available for download on the UE website: www.
ueonline.com/resource-center/certifications/
3
THE ONLY FIELD REPLACEABLE PARTS ARE THE BATTERY
PACK AND FLEXSENSE™ SENSOR. ANY SUBSTITUTION OF
COMPONENTS OTHER THAN THE BATTERY AND GAS
SENSOR MODULE WILL INVALIDATE THIRD-PARTY ISSUED
APPROVALS AND CERTIFICATIONS, AND MAY IMPAIR
SUITABILITY FOR HAZARDOUS LOCATIONS.
Global Certification
IECEx ETL 21.0065X
Ex db ia op is [ia] IIC T4 Gb
Tamb: X
EU Certification
ITS-I21ATEX31360X
II 2 (2) G Ex db ia op is [ia] IIC T4 Gb
Tamb: X*
North American Certification
Class I Div. 1, Groups A, B, C & D, T4
USA: Class I, Zone 1, AEx db ia op is [ia] IIC T4 Gb
Enclosure Type 4X, IP66**
Canada Certification:
ETL21CA104546645X
Class I, Zone 1, Ex db ia op is [ia] IIC T4 Gb
Tamb: X*
IM_TCD60 02