2.6.5 Universal Mount
Remove hardware from packaging (see Figure 26).
Feed straps [8] through bracket [3] using the bolt holes (see
fi gure 26).
Wrap steel straps around pipe or object to mount to and tighten
using screw [9] (See fi gure 27).
Mount device by hooking onto top pin of bracket plate (see
fi gure 28).
Secure with pin [5] by pushing though the bottom holes in the
bracket (see fi gure 29).
[8]
[3]
Figure 26
[5]
Figure 28
2.6.6 Device removal from mounting bracket
plate
Pull attached pin [5] through bottom holes using the pull ring.
Pull device up and unhook from mounting bracket plate [3].

2.7 Optional Remote Mount Kit for Sensors

Users can place the sensor close to where gas can
collect while position the Vanguard in a location
more suitable for viewing during bump testing and
calibrations. Examples include sensors installed in
vaults, containers, or low to the ground.
The distance is limited to 9 feet (2.7
meters) due to the I.S. rating of the
sensor and can only use UE kit (Part #
62169-66).
Included in the kit (Figure 30):
Remote sensor bracket [8]
Cable [9]
Transmitter adapter [10]
This kit works with the same sensors
that are shipped with the Vanguard
transmitter. It is also possible to
retrofi t existing installations with the
[9]
kit.
Figure 27
2.8 Antenna Placement
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES:
MAY NOT CAUSE HARMFUL INTERFERENCE; MUST ACCEPT
ANY INTERFERENCE, INCLUDING THAT WHICH MAY CAUSE
UNDESIRED OPERATION OF THE DEVICE.
TO COMPLY WITH IC RF EXPOSURE COMPLIANCE
REQUIREMENTS, THE ANTENNA USED FOR THIS DEVICE
MUST BE INSTALLED TO PROVIDE A SEPARATION DISTANCE
Figure 29
OF AT LEAST 20 CM FROM ALL PERSONS.
FCC ID SJC-ETERNA2 CONTAINS IC 5853(A)-ETERNA2 CE0976
WALL MOUNTING COULD AFFECT THE SIGNAL STRENGTH
OF THE DEVICE.

2.8.1 Antenna Placement Considerations

The antenna supplied with the device is an omnidirectional
antenna, affi xed to the product. In order to facilitate
communication with other WirelessHART devices as part
of a wireless mesh network, it is recommended that the
device be mounted with minimum obstructions and noise
interference. The maximum range of communication
between the device and other devices (instrumentation,
repeaters, gateways) is 750 feet (229 meters).