United Electric Controls VANGUARD Installation And Operation Instruction Manual page 14

Wirelesshart toxic & combustible gas detector
Table of Contents

Advertisement

3.3.5 HART Command 129 Write
Calibration Point
Request bytes:
Bytes
Format
Description
0-3
Float
Concentration of gas used during calibration
Response bytes:
Bytes
Format
Description
0-3
Float
Concentration of gas used during calibration
Command Specific Response Code:
Code
Class
Description
0
Success
No command specific errors
2
Error
Concentration too low
3
Error
Concentration too high
4
Error
Concentration not valid
5
Error
Incorrect number of data bytes received
3.3.6 HART Command 131 Read Sensor
Activation State
Request bytes:
Bytes
Format
Description
None
Response bytes:
Bytes
Format
Description
0-1
Unsigned-16
Sensor type (0=Not Activated)
Command Specific Response Code:
Code
Class
Description
0
Success
No command specific errors
3.3.7 HART Command 132 Read Base Unit
Configuration String
Request bytes:
Bytes
Format
Description
None
Response bytes:
Bytes
Format
Description
Unit Configuration String, (e.g., UEC100 SW
0-39
Latin-1
2.20 HW 1.21)
Command Specific Response Code:
Code
Class
Description
0
Success
No command specific errors
3.3.8 HART Command 133 Read Sensor
Module Configuration String
Request bytes:
Bytes
Format
None
Response bytes:
Bytes
Format
0-39
Latin-1
Command Specific Response Code:
Code
Class
0
Success
3.3.9 HART Command 138 Read Sensor
Type String
Table 6
Request bytes:
Bytes
Format
0
Unsigned 8
Response bytes:
Bytes
Format
0
Unsigned 8
1-16
ISO-Latin1
Command Specific Response Code:
Code
Class
0
Success
1
Error
2
Error
Table 7
Table 8
14
Description
Description
Sensor Module Configuration String (e.g.,
H2S: 02031 08035278 02 MIPEX-2_25.6)
Description
No command specific errors
Description
Device Variable Code
Description
Device Variable Code
Variable Type String
Description
No command specific errors
Wrong Number of Data Bytes
Invalid Selection
IM_TCD60 02
Table 9
Table 10