Device Approvals - United Electric Controls VANGUARD Installation And Operation Instruction Manual

Wirelesshart toxic & combustible gas detector
Table of Contents

Advertisement

Top foam for packaging
BASE UNIT
Bottom foam for packaging
DEVICE IS SHIPPED WITHOUT THE SENSOR OR BATTERY
INSTALLED. BOTH MUST BE INSTALLED PRIOR TO USE. SEE
SECTION 2.0 INSTALLATION FOR FURTHER INFORMATION.
1.2.1 Sensors
One FLEXsense™ sensor is shipped (but uninstalled) with
the base unit (if ordered in that confi guration). Additional,
spare FLEXsense™ sensors may be ordered and will ship
separately.
1.2.2 Battery
The battery pack is shipped separately from the
base unit as it contains lithium which is regulated in
transportation by the U.S. Department of Transportation,
the International Air Transport Association, International
Civil Aviation Organization, and European Ground
Transportation of Dangerous Goods.

1.3 Device Approvals

THIS DEVICE IS SUITABLE FOR HAZARDOUS LOCATIONS
PER CERTIFICATIONS (SEE BELOW) OR NON-HAZARDOUS
LOCATIONS ONLY.
THIS DEVICE MEETS ALL REQUIREMENTS FOR STANDARDS
LISTED ON THE CERTIFICATIONS (SEE BELOW).
FLEXsense™ SENSOR
Figure 3
5003390
*Ambient operating temperature range may vary with sensor type.
See datasheet for sensor specifi cations.
**Enclosure Type 4X and IP66 rating excludes sensor.
The device has been certifi ed in accordance with the
Figure 4
applicable requirements of the following standards:
Each certifi cate lists the standard, along with standard
revision or date, which this Vanguard product meets. See
ITS16ATEX18474X for EN Standards,
See IECEx ETL 16.0016X for IECEx Standards. The North
America, ATEX (Europe), and IEC (International) certifi cates
are available for download on the UE website: www.
ueonline.com/resource-center/certifi cations/
3
THE ONLY FIELD REPLACEABLE PARTS ARE THE BATTERY
PACK AND FLEXSENSE™ SENSOR. ANY SUBSTITUTION OF
COMPONENTS OTHER THAN THE BATTERY AND GAS
SENSOR MODULE WILL INVALIDATE THIRD-PARTY ISSUED
APPROVALS AND CERTIFICATIONS, AND MAY IMPAIR
SUITABILITY FOR HAZARDOUS LOCATIONS.
Global Certifi cation
IECEx ETL16.0016X
Ex db ia op is [ia] IIB T4 Gb
Tamb: X
EU Certifi cation
ITS 16 ATEX 18474X
II 2 (2) G Ex db ia op is [ia] IIB T4 Gb
Tamb: X*
North American Certifi cation
Class I Div. 1, Groups C & D, T4
USA: Class I, Zone 1, AEx db ia op is [ia] IIB T4 Gb
Enclosure Type 4X, IP66**
Canada Certifi cation:
ETL22CA104832805X
Class I, Zone 1, Ex db ia op is [ia] IIB T4 Gb
Tamb: X*