2.6.2 Standard Mount - Horizontal
Remove hardware from packaging (see Figure 15).
Place one pipe mount adaptor [1] onto desired location vertically
on pipe and slide U-bolt [2] through holes.
Slide mounting bracket plate [3] onto U-bolt [2] and secure with
(2x) hex nuts [4]. Do not tighten.
Repeat step 2 with second pipe mount adaptor [1] also sliding
U-bolt [2] through mounting bracket plate [3] and securing with (2x)
hex nuts [4].
Once position is set, tighten (4x) hex nuts using 1/2" wrench.
Mount device by hooking onto top pin of mounting bracket plate
(see Figure 18).
Push attached pin [5] through bottom holes to secure device to
the bracket (see Figure 19).
[1]
[3]
[2]
[4]
[5]
Figure 18
2.6.3 Standard Mount - Wall
WALL MOUNTING COULD AFFECT THE SIGNAL STRENGTH
OF THE DEVICE.
Remove hardware from packaging (see Figure 20).
Hold mounting bracket plate [3] against wall/flat surface and
screw tightly into place using (4x) mounting holes (0.40" dia.).
Note: Mounting screws [6] not UE provided.
Mount device by hooking onto top pin of mounting bracket plate
(see Figure 21).
Push attached pin [5] through bottom holes to secure device to
the bracket (see Figure 22).
[3]
[6]
[5]
Figure 20
2.6.4 Magnetic Mount
CAUTION: MAGNETS MAY CAUSE PINCH POINTS.
MAGNET CONTACT FORCE IS DEPENDENT ON SURFACE
CONDITION AND FLATNESS. MOUNT TO FLAT, DRY,
CLEAN SURFACES THAT ARE NOT SUBJECT TO EXTREME
ENVIRONMENTAL CONDITIONS..
THIS SOLUTION SHOULD NOT BE USED FOR OVERHEAD
MOUNTING.
Remove hardware from packaging (see Figure 23).
Attach device to mounting bracket by hooking onto top pin of
mounting bracket plate (see Figure 24).
Push attached pin [5] through bottom holes to secure device to
the bracket (see Figure 24).
Figure 19
Align magnet mount [7] to mounting location.
Place onto location gently or using a top-to-bottom "peeling"
motion (Figure 25).
Use the same top-to-bottom peeling motion to remove the
mount from the wall.
[7]
[5]
Figure 23
Figure 21
7
Figure 22
Figure 24
Figure 25
IM_TCD60 02