Summary of Contents for GILBARCO VEEDER-ROOT Nano Nozzle Reader-T
Page 1
Important Safety Information Before You Begin Installing nano Nozzle Reader-T on Wiggins Nozzles nNR-T Maintenance Required Tools The following tools are required to install the nano Nozzle Reader-T on Wiggins nozzles: • Pliers • 2-mm T-Handle Allen Key (not ball ended) ®...
Page 2
Typical transmission power: 3dbm (2mW) RFID to FuelOpass: 108-131 kHz Hazardous Area Zone 1 Explosive atmosphere (Ex) Exi/Exia: Intrinsically Safe/Sécurité Intrinsèque Group IIB type product Temperature Class: T3 Rated Temperatures: -40°<=T'amb<=+60°C Page 2 MDE-5404A Nano Nozzle Reader-T Service Manual · August 2018...
Page 3
. and the safety of others to understand the procedures before beginning work. DEF is non-flammable. Therefore, explosion and fire safety warnings do not apply to DEF lines. MDE-5404A Nano Nozzle Reader-T Service Manual · August 2018 Page 3...
Page 4
Subpart S of 29 CFR Part 1910 - Electrical Hazards, 29 CFR Part 1910.333 contains specific Lockout/Tagout provision for electrical hazards. Page 4 MDE-5404A Nano Nozzle Reader-T Service Manual · August 2018...
Page 5
Ensure that all power to the unit is switched off before opening the door to the unit and during installation of the kit. Match the parts received in the kit with “Parts List” page MDE-5404A Nano Nozzle Reader-T Service Manual · August 2018 Page 5...
Page 6
When replacing the battery, use 3.6 V Battery Pack (M09680B148) only. To install the nano Nozzle Reader-T on Wiggins nozzles, proceed as follows: Note: The nNR-T is provided with two pins, which are already located in their slots ready to be secured.
Page 7
Figure 4: Placing the nNR-T on Wiggins Nozzle Secure the nNR-T by applying pressure on the two pins, which are already located in their slots (see Figure Figure 5: Securing the nNR-T MDE-5404A Nano Nozzle Reader-T Service Manual · August 2018 Page 7...
Page 8
Remove the nNR-T unit from the Wiggins nozzle by pulling the two pins upwards, and then sliding the nNR-T assembly off the nozzle. Note: DO NOT open the unit at the location of installation. Page 8 MDE-5404A Nano Nozzle Reader-T Service Manual · August 2018...
Page 9
Figure 6: Removing the Top Cover Screws Remove the cover. The battery pack is located on the inner side of the top cover (see Figure Figure 7: Removing the Top Cover MDE-5404A Nano Nozzle Reader-T Service Manual · August 2018 Page 9...
Page 10
Secure the top lid with the four M3 screws using the 2-mm Long T-Handle Allen Key. Reinstall the unit onto the nozzle (refer to “Installing nano Nozzle Reader-T on Wiggins Nozzles” page Page 10 MDE-5404A Nano Nozzle Reader-T Service Manual · August 2018...
Page 11
Maintenance This page is intentionally left blank MDE-5404A Nano Nozzle Reader-T Service Manual · August 2018 Page 11...
Need help?
Do you have a question about the Nano Nozzle Reader-T and is the answer not in the manual?
Questions and answers