Electrical Data - Beko BEKOMAT 32U F Instructions For Installation And Operation Manual

Condensate drain
Table of Contents

Advertisement

Electrical data

Pos: 29 / Beko Techni s che D ok um ent at i o n/ Ü ber schr i f t en/ 1/ El e kt r i s che D at en @ 0\ m od_11836384513 71_150 98. docx @ 15115 @ 1 @ 1
6
Electrical data
Pos: 30 / Beko Techni s che D ok um ent at i o n/ El e kt r i s ch e D at en/ BEKO M AT/ E l e kt r i s che D at en BM 32U / 33U @ 4\ m od_13577374 05732_ 15098. docx @ 29609 @ @ 1
Supply voltage
(see type plate)
Power consumption
Recommended
cable-jacket diameter
Recommended
wire cross section
Spring-loaded terminal
(voltage supply/relay)
Recommended
wire cross section
Screw terminal
(voltage supply)
Recommended
wire cross section
Spring-loaded terminal
(external test)
Recommended
wire cross section
Screw terminal
(relay/external test)
Recommended
stripping of cable jacket
(voltage supply/relay)
Recommended
stripping of cable jacket
(external test)
Recommended
length of the wire end tube
Spring-loaded terminal
Recommended
length of the wire end tube
Screw terminal
Connection data of the potential-
free contact
Switch to load*)
Connection data of the
potential-free contact
Switch to low signal*)
Connection data of the
external test contact
Protection class
Overvoltage category
(IEC 61010-1)
VAC = V alternating current
VDC = V direct current
*)
The switching of loads means that the properties of the contact are no longer suitable
for the switching of low signals.
Pos: 31 / - - - - Sei t enum br uch - - - - @0\ m od_1157028099015_ 0. docx @ 15320 @ @ 1
8
95...240 VAC ±10% (50...60 Hz) /100...125 VDC ±10%
or
24...48 VAC ±10% (50...60 Hz) / 18...72 VDC ±10%
P = 0,6 ... 3 VA (W)
Ø 5,0...10 mm (0,20"...0,39")
0,75...1,5 mm² (AWG 16...20)
0,75...2,5 mm² (AWG 14...20)
0,75...1,0 mm² (AWG 18...20)
0,75...1,5 mm² (AWG 16...20)
~ 30 mm (~ 1.18")
~ 90 mm (~ 3.54")
~ 8 mm (~ 0.31 inch)
~ 6 mm (~ 0.24 inch)
AC: max. 250V / 1A
DC: max. 30V / 1A
min. 5 VDC / 10 mA
on the unit side 5 VDC; switching current ≥ 0,5 mA
IP 67
II
BEKOMAT® 32U F

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bm32uf

Table of Contents