Electrical installation

Pos: 49 / Beko Techni s che D ok um ent at i o n/ Ü ber schr i f t en/ 1/ El e kt r i s che I nst al l a t i o n @ 0\ m od_118363850 7355_1 5098. docx @ 15116 @ 1 @ 1
10 Electrical installation
Pos: 50 / Beko Techni s che D ok um ent at i o n/ Si c h er hei t / G ef ahr N et zspannung 1 s/ w @ 0\ m od_1184148186948 _15098. docx @ 15122 @ @ 1
Danger!
Supply voltage!
There is the risk of an electric shock involving injury or death when coming into contact
with non-insulated components carrying supply voltage.
Pos: 51 / Beko Techni s che D ok um ent at i o n/ Si c h er hei t / M aßnahm en N et zspann ung BM 31U / 32U / 33 U @ 7\ m od_13904671 97804_1 5098. docx @ 38070 @ @ 1
Measures:
During electric installations, all regulations in force need to be adhered to (e.g. VDE 0100 / IEC 60364).
When the control unit is open, service and installation works must only be undertaken when the
system is deactivated.
The removed control unit has no IP degree of protection.
All types of electrical works must be carried out by authorized and qualified personnel only.
Pos: 52 / Beko Techni s che D ok um ent at i o n/ I nst al l a t i o n/ B EKO M AT/ E l e kt r I nst al l a t i o n H i n w e i s e BM 32 U / 33U al l g . @ 4\ m od_135772888407 9_1509 8. docx @ 29541 @ @ 1
16
Note:
Power supply connection:
1. Read the permissible supply voltage on the type
plate and make sure this voltage is observed.
2. For the supply voltage, a reliably accessible sepa-
rator must be provided close-by (e.g. power plug
or switch), which separates all current-carrying
conductors.
3. At a low voltage supply
(< 50 VAC / < 75 VDC), only use a protective ex-
tra-low-voltage.
4. Carry out installation in accordance with
VDE 0100 / IEC 60364.
5. Observe the terminal assignment.
6. Do not install when the device is energized.
7. Unscrew the screws (1) and remove the upper
part of the cover (2).
8. Unscrew the threaded cable connection (3), re-
move the plug (if there is one), and lead the cable
(4) for the power supply through.
9. Connect the cable (4) with terminals X1 (1.1, 1.2)
(5).
10.Install the cables as shown (see also terminal as-
signment in the following text).
11.Tighten the threaded cable connection (3) with a
slightly sealing effect.
12.Put on the upper part of the cover (2) and tighten
the screws (1) fingertight.