Beko BEKOMAT 32U F Instructions For Installation And Operation Manual page 17

Condensate drain
Table of Contents

Advertisement

Pos: 53 / Beko Techni s che D ok um ent at i o n/ I nst al l a t i o n/ B EKO M AT/ K l e m m enbel e gung BM 32U / 33 U @ 4\ m od_1354692952 721_15 098. docx @ 29135 @ @ 1
Terminal assignment supply voltage (operating voltage)
X 1
X 2
Terminal assignment low voltage (operating voltage)
X 1
X 2
BEKOMAT® 32U F
Power supply
X 3
X 1.1 L/+
X 1.2 N/-
L = Outer conductor
N = Neutral conductor
X 3
Power supply
X 1.1 L/+
X 1.2 N/-
Connection of the potential-free contact and of
the external test:
1. Selection of the suitable cable.
2. Connection to X2 and X3, as shown on the left.
3. The installation steps are the same as for the
power supply connection.
4. If the potential-free contact carries voltage that is
dangerous in the case of contact, a corresponding
separator must also be provided, as described
above.
5. When using the potential-free contacts and the
connection external test, sufficient clearance to
the other parts of the unit, or suitable insulation in
accordance with EN 60664-1 must be ensured.
6. When using a multiwire, common line for the con-
nection of the potential-free contact and the exter-
nal test, this line must be suitable for the highest
occurring voltage and the intended temperature
range with regard to its nominal ratings.
Electrical installation
17