Danger!
Supply voltage!
There is the risk of an electric shock involving injury or death when coming into contact
with non-insulated components carrying supply voltage.
Pos: 12 / Beko Techni s che D ok um ent at i o n/ Si c h er hei t / M aßnahm en N et zspann ung BM 31U / 32U / 33 U @ 7\ m od_13904671 97804_1 5098. docx @ 38070 @ @ 1
Measures:
During electric installations, all regulations in force need to be adhered to (e.g. VDE 0100 / IEC 60364).
When the control unit is open, service and installation works must only be undertaken when the
system is deactivated.
The removed control unit has no IP degree of protection.
All types of electrical works must be carried out by authorized and qualified personnel only.
Pos: 13 / Beko Techni s che D ok um ent at i o n/ Si c h er hei t / Si c her he i t shi n w ei s e, w ei t er e BM ( ni c ht Ex, ni c ht I F) @ 0\ m od_1183616103 770_15 098. docx @ 15100 @ @ 1
Further safety instructions:
For installation and operation, the national regulations and safety codes in force must also be adhered
to.
Do not use the BEKOMAT
Regarding the inlet screw joints, excessive tightening forces must be avoided. This applies in particular
to conical screw joints.
®
The BEKOMAT
32U will only function when voltage is applied.
Do not use the test button for permanent drainage.
Use genuine spare parts only. This is imperative to ensure perfect functioning.
Pos: 14 / Beko Techni s che D ok um ent at i o n/ Si c h er hei t / Zusat z Si c her he i t shi n w ei s e BM 3 1/ 32 SA +31U / 32 U SA @ 0\ m od_1185351 496993 _15098. docx @ 15150 @ @ 1
Additional advice:
The removed control unit has no IP degree of protection.
During installation, use spanner flat at the feed pipe (wrench size SW27) as a back rest.
The service unit must not be dismantled.
Pos: 15 / Beko Techni s che D ok um ent at i o n/ Si c h er hei t / Vor si c ht Fehl f unkt i on @ 0\ m od_121437809 6290_15 098. docx @ 15237 @ @ 1
Caution!
Malfunction during operation!
Through incorrect installation and poor maintenance, malfunction may occur at the
BEKOMAT.
Condensate which is not discharged may cause damage to plants and in production
processes.
Pos: 16 / Beko Techni s che D ok um ent at i o n/ Si c h er hei t / M aßnahm en Feh l f unkt i o nen BM @ 0\ m od_12143784 34025_1 5098. docx @ 15238 @ @ 1
r
Measures:
Condensate drainage which is reliable in performance directly optimizes the compressed-air quality.
To prevent damage and breakdowns, it is imperative to observe the following:
Exact compliance with the specifications of use and with the performance parameters of the
BEKOMAT, in connection with the case of application (see "Proper use" section)
Exact compliance with the installation- and operation instructions in this manual
Regular maintenance and control of the BEKOMAT in accordance with the instructions in this oper-
ating manual