10.1 Disassembly for CRT replacement

TOP PREVIOUS NEXT
1. Discharge the CRT as instructed in the "safety precautions" section and remove 2nd anode button
from the CRT.
2. Remove speaker modules (R and L)
3. Perform complete removal of chassis, as instructed in "disassembly for service" section.
NOTE
When remounting the CRT, reuse the metal sheet located in the lower part of the cabinet holding
the CRT, hold with screws to the cabinet. This metal sheet is not supplied with the CRT
replacement.
CRT replacement
1. Perform "disassembly for CRT replacement" procedure.
2. Insure that the CRT H.V. Anode button is discharged before handling the CRT. Read the "safety
precautions" section on handling the picture tube.
3. Remove the components from the CRT neck and place the cabinet face down on a soft pad.
4. Note the original order for the CRT mounting hardware as they are remove from the CRT
mounting brackets at each corner of the CRT.
5. Remove the CRT with the degaussing coil and the dag ground braid attached.
NOTE
To remove the four brackets holding the degauss coil from the corners of the CRT, first remove
the CRT from the cabinet, then remove the brackets by pressing the tab on the bracket and pull
upwards. These brackets are included in the degauss coilkit, for part number, please see parts list
section
http://tsn.pstc.panasonic.com/viewing/NA/CT-36SL13G/SVC/s1001000000.html (1 of 2)05.12.2008 0:01:40