This standard work checklist is to be used by the installer in conjuction with, not instead of, the instructions contained in this installation
manual.
Customer:
Lot/Address
Model:
WARNING! Risk of Fire or Explosion! Failure to install fireplace acording to these instructions can lead to a fire or
explosion.
Fireplace Install 6HFWLRQ  SDJH 
Verified that the chase is insulated and sealed.
5HTXLUHG WRS VWDQGRIIV LQVWDOOHG
Required non-combustible board is installed.
Verified clearances to combustibles.
Fireplace is leveled and secured.
Hearth extension size/height decided.
Outside air kit installed.
Optional Heat Zone has been installed by a qualified service technician.
)DQ DLU NLW LQVWDOOHG
Chimney Section 5
 SDJH 
Chimney configuration complies with diagrams.
Chimney installed, locked and secured in place with proper clearance.
Chimney air kit installed.
Firestops installed.
Attic insulation shields installed.
Roof flashing installed and sealed.
Terminations installed and sealed.
Electrical Section 4 SDJH 
Switch wires properly installed.
Finishing Section 7 SDJH 
Combustible materials
Combustible
materials not
not installed
installed in in non-
Verified all clearances meet installation manual requirements.
Mantels and wall projections comply with installation manual requirements.
Protective hearth strips and hearth extension installed per manual requirements.
Fireplace Setup Section 8 SDJH 
All packaging and protective materials removed.
Firebrick, baffle and ceramic blanket installed correctly.
Facia and doors properly installed.
Manual bag and all of its contents are removed from inside/under the fireplace and
given to the party responsible for use and operation.
All packaging materials are removed from inside/under the fireplace.
Hearth & Home Technologies recommends the following:
Photographing the installation and copying this checklist for your file.
That this checklist remain visible at all times on the fireplace until the installation is complete.
Comments: Further description of the issues, who is responsible (Installer/Builder/Other Trades, etc.) and corrective action needed:
_________________________________________________________________________________________________
________________________________________________________________________________________________________
________________________________________________________________________________________________________
Comments communicated to party responsible
Heatilator • C40-C Constitution Installation Manual • 4186-901 • Rev H • 03/23
ATTENTION INSTALLER:
Follow this Standard Work Checklist
Date Installed:
Location of Fireplace:
Installer:
Dealer/Distributor Phone #
&&
Serial #:
non-combustible
combustible areas
areas.
__________________________ by ______________________on _________