Installation
Remove the knockout or cover plate from the top of the
¿UHSODFH DQG GLVFDUG LW 6HH )LJXUH 
&XW D  LQ  PP KROH LQ WKH LQVXODWLRQ ERDUG DQG
UHPRYH LW DV SHU WKH GLPHQVLRQV VKRZQ LQ )LJXUH 
Adapter
Mounting Plate
Starter Pipe
Cover Plate
Figure 3.25
Determine the necessary length of starter pipe from
7DEOH  DQG FXW DV UHTXLUHG
Table 3.1
Run Length
20 - 40 ft (6-12 m)
10 - 20 ft (3 - 6 m)
3 - 10 ft (1 - 3 m)
NOTE:
It is important the pipe length be adhered to
RU LW ZLOO DIIHFW WKH SHUIRUPDQFH RI \RXU ¿UHSODFH
2Q WKH PRXQWLQJ SODWH KDQG EHQG WKH WDEV GRZQZDUG
6OLGH WKH WDEV RYHU WKH RXWVLGH RI WKH VWDUWHU SLSH 6HFXUH
with four sheet metal screws included in fasteners
SDFNDJH )LJXUH 
Heatilator • C40-C Constitution Installation Manual • 4186-901 • Rev H • 03/23
4 in.
(102 mm)
3¾ in. (95 mm)
C L
Cut out and
remove the
insulation
Cut Pipe Length
16 in. (406 mm)
 IXOO SLHFH RI SLSH
24 in. (607 mm)
30-1/2 in. (775 mm)
 IXOO SLHFHV RI SLSH
Figure 3.26
6OLGH WKH VWDUWHU SLSH LQWR WKH ¿UHSODFH PDWFKLQJ WKH
KROHV LQ WKH SODWH WR WKH KROHV RQ WKH ¿UHSODFH
Place the adapter on the mounting plate lining up holes.
Using four sheet metal screws included in the kit, secure
WKH DGDSWHU DQG PRXQWLQJ SODWH RQ WKH ¿UHSODFH $IWHU
VHFXULQJ WR WKH ¿UHSODFH WDSH GRZQ WKH DGDSWHU HGJHV
WR WKH WRS RI WKH ¿UHSODFH ZLWK DOXPLQXP WDSH WR SUHYHQW
leakage.
Determine the location for the air register and fan
KRXVLQJ DVVHPEO\ &XW D  LQ [  LQ  PP
[  PP KROH EHWZHHQ IUDPLQJ PHPEHUV ZDOO VWXGV RU
ÀRRU MRLVWV  $WWDFK WKH EUDFNHWV WR WKH IDQ KRXVLQJ ZLWK
WKH VFUHZV SURYLGHG 7KH EUDFNHWV FDQ EH URWDWHG ƒ
DQG PRXQWHG WR WKH EDFN VLGH RI WKH  [  LI QHFHVVDU\
See Figure 3.27.
NOTICE:
7KH IDQ DQG HOHFWULFDO FRQQHFWLRQV PXVW EH
DFFHVVLEOH IRU VHUYLFLQJ SHU ORFDO FRGH UHTXLUHPHQWV
$WWDFK HQRXJK  LQ  PP %9HQW DV UHTXLUHG IRU \RXU
installation to the fan housing. A maximum of (4) 90°
elbows are allowed. Screw the B-vent to the adapter.
$OVR VFUHZ WKH %YHQW WR WKH RXWOHW ER[ RQ WKH IDQ
KRXVLQJ 6HH )LJXUH  Support duct at intervals
RI QR JUHDWHU WKDQ  IW  P DV UHTXLUHG E\ ORFDO FRGH
WARNING! Risk of Fire!
FOHDUDQFHV VSHFL¿HG
$ PLQLPXP  LQ  PP DLU FOHDUDQFH PXVW EH
PDLQWDLQHG DW WKH EDFN DQG  LQ  PP WR WKH VLGHV
RI WKH ¿UHSODFH DVVHPEO\
Pipe must be cut
to correct length.
See Table 3.1
&RPSO\ ZLWK DOO PLQLPXP