Read and understand this manual before operating your air tool
Scorpion
Handheld HEPA Vacuum
Model: SC-100
• Designed for FOD Control, Dustless Sanding, and General Cleanup
• Dry Recovery Only
Scan this QR code for
online instructions and
documentation, or visit
www.ClaytonHowTo.com
WARNING
SAFETY LEGEND
Read and understand operator's manual before
using this equipment.
Hearing protection is recommended when
operating this equipment.
• A HEPA Filter must be installed in this vacuum at all times
• If this vacuum is used to collect hazardous material, appropriate personal protective equipment may be required
• Any alteration to this equipment by a third party will nullify its warranty
• 90 PSI Max air supply pressure
SC-100
WARNING
WARNING
SC-100_cover
Eye protection is required when operating this
equipment.
Respiratory protection is recommended
operating this equipment.
WARNING
WARNING
December 05, 2022

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Scorpion SC-100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Clayton Scorpion SC-100

  • Page 1 Safety – Operation – Maintenance Keep this document in a safe place Read and understand this manual before operating your air tool Scorpion Handheld HEPA Vacuum Model: SC-100 • Designed for FOD Control, Dustless Sanding, and General Cleanup • Dry Recovery Only Scan this QR code for online instructions and documentation, or visit...
  • Page 2: Table Of Contents

    Shoulder Strap........................12 Illustrated Parts Breakdown....................13 Illustrated Parts Breakdown....................14 Limited Lifetime Warranty Terms And Conditions ..............15 Repair or Warranty Contact Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 SC-100 www.DustlessMadeSimple.com • Sales@JClayton.com Page 2...
  • Page 3: Applications & Environments

    Adapter Hose 4ft - 1in Hose to 1-1/4in Smooth Cuff 671-VHA16-022 Compressed Airline 1/4in x 4ft 922-A04H04 Compressed Airline 3/8in X 30ft 922-A06H30 Repair or Warranty Contact Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 SC-100 www.DustlessMadeSimple.com • Sales@JClayton.com Page 3...
  • Page 4: Specifications & Requirements

    PERFORMANCE: Vacuum Flow ..................................45 CFM (77 SCMH) Vacuum Suction ..................................50 inH O (345 kPa) Repair or Warranty Contact Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 SC-100 www.DustlessMadeSimple.com • Sales@JClayton.com Page 4...
  • Page 5: Getting Started

    Compressed Air Valve Shoulder Strap Shoulder Strap Mojave Buckle Mojave Buckle Canister HEPA Filter Pre‑Filter SC-100_005 Repair or Warranty Contact Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 SC-100 www.DustlessMadeSimple.com • Sales@JClayton.com Page 5...
  • Page 6: Compressed Air Fittings

    • Install a new compressed air coupler. Compressed Air Plug Compressed Air Bushing Compressed Air Bushing Compressed Air Coupler SC-100_006 Repair or Warranty Contact Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 SC-100 www.DustlessMadeSimple.com • Sales@JClayton.com Page 6...
  • Page 7: Before Each Use

    Compressed Air Tool Supply Compressed Air Valve ON SC-100_010 Repair or Warranty Contact Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 SC-100 www.DustlessMadeSimple.com • Sales@JClayton.com Page 7...
  • Page 8: Empty The Vacuum

    • Replace the inlet cap on the canister and rotate clockwise approximately one (1) complete turn, until snug. Inlet Cap Top Edge of Canister Canister SC-100_011 Repair or Warranty Contact Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 SC-100 www.DustlessMadeSimple.com • Sales@JClayton.com Page 8...
  • Page 9: Safe Debris Removal

    • Continue to tilt and lightly shake the Scorpion until all debris has been removed from the canister. Canister Support Vacuum Hose SC-100_012 Vacuum Inlet Repair or Warranty Contact Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 SC-100 www.DustlessMadeSimple.com • Sales@JClayton.com Page 9...
  • Page 10: Pre-Filter Change

    • Replace the inlet cap on the canister and rotate clockwise until snug, approximately one (1) complete turn. Top Edge of Canister Canister Repair or Warranty Contact Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 SC-100 www.DustlessMadeSimple.com • Sales@JClayton.com Page 10...
  • Page 11: Hepa Filter Change

    Canister • Refer to the directions on the timer card to activate it. Repair or Warranty Contact Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 SC-100 www.DustlessMadeSimple.com • Sales@JClayton.com...
  • Page 12: Shoulder Strap

    • The Shoulder Strap buckles clip A to two (2) Mojave Buckles B on the Inlet Cap. • Adjust the Shoulder Strap by sliding buckle C. SC-100_016 Repair or Warranty Contact Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 SC-100 www.DustlessMadeSimple.com •...
  • Page 13: Illustrated Parts Breakdown

    Fitting Plug 1/4in HiFlow x 1/4in MNPT SE103210-PFSM-Z Screw, FH100, SS, 1032 X .625 SC-100_018 Repair or Warranty Contact Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 SC-100 www.DustlessMadeSimple.com • Sales@JClayton.com Page 13...
  • Page 14: Illustrated Parts Breakdown

    Shoulder Strap Mojave Buckles RE0618-PDATB-Z Rivet Blind 3/16 x 0.563 Open Alum Blk (.251-.375) SC-100_017 Repair or Warranty Contact Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 SC-100 www.DustlessMadeSimple.com • Sales@JClayton.com Page 14...
  • Page 15: Limited Lifetime Warranty Terms And Conditions

    Repair within the Continental US During the first 90 days of the warranty period, Clayton will provide parts and labor to the customer’s site at no charge or pay freight costs associated with returning the products for repair to a Clayton selected service location and repair the product at no charge. Clayton personnel will determine the best way to repair the product.
  • Page 16 Clayton products are proudly made in the USA Repair or Warranty Contact Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084 www.DustlessMadeSimple.com • Sales@JClayton.com...

Table of Contents