Table Of Contents - Daikin Perfera ARXM25A Service Manual

Table of Contents

Advertisement

Table of Contents

Service manual
4
draft - 21/12/2023 13:09
Table of Contents
1.1
Meaning of warnings and symbols.................................................................................................................................
1.2
Dangers ...........................................................................................................................................................................
1.3
Warnings .........................................................................................................................................................................
1.4
Cautions .......................................................................................................................................................................... 13
1.5
Notices ............................................................................................................................................................................ 13
3.1
To display the error code on the wireless remote controller........................................................................................ 15
3.2
To reset the error code via remote controller ............................................................................................................... 15
3.3
To reset the error code via outdoor unit ....................................................................................................................... 15
3.4
To perform a test run...................................................................................................................................................... 15
3.4.1
To perform a test run using the wireless remote control ............................................................................. 15
3.5
Error based troubleshooting........................................................................................................................................... 16
3.5.1
A1-00 - PCB abnormality ............................................................................................................................... 16
3.5.2
A5-00 - Outdoor unit: High pressure peak cut / freeze protection problem ............................................... 17
3.5.3
A6-00 - Indoor unit fan motor abnormality .................................................................................................. 17
3.5.4
AH-00 - Streamer unit abnormality............................................................................................................... 18
3.5.5
C4-00 - Heat exchanger temperature sensor problem................................................................................. 18
3.5.6
C9-00 - Room thermistor abnormality .......................................................................................................... 19
3.5.7
E1-00 - Outdoor unit: PCB defect.................................................................................................................. 19
3.5.8
E3-00 - Outdoor unit: Actuation of high pressure switch............................................................................. 20
3.5.9
E5-00 - Outdoor unit: Overheat of inverter compressor motor................................................................... 21
3.5.10
E6-00 - Outdoor unit: Compressor startup defect........................................................................................ 22
3.5.11
E7-00 - Outdoor unit: Malfunction of outdoor unit fan motor .................................................................... 23
3.5.12
E8-00 - Outdoor unit: Power input overvoltage ........................................................................................... 24
3.5.13
EA-00 - Outdoor unit: Cool/heat switchover problem ................................................................................. 24
3.5.14
F3-00 - Outdoor unit: Malfunction of discharge pipe temperature............................................................. 25
3.5.15
F6-00 - Outdoor unit: Abnormal high pressure in cooling............................................................................ 26
3.5.16
3.5.17
H0-00 - Outdoor unit: Voltage/current sensor problem .............................................................................. 28
3.5.18
H3-00 - Outdoor unit: Malfunction of high pressure switch ........................................................................ 29
3.5.19
H6-00 - Outdoor unit: Malfunction of position detection sensor ................................................................ 29
3.5.20
H8-00 - Outdoor unit: Malfunction of compressor input system................................................................. 30
3.5.21
H9-00 - Outdoor unit: Malfunction of outdoor air thermistor ..................................................................... 31
3.5.22
J3-00 - Outdoor unit: Malfunction of discharge pipe thermistor................................................................. 31
3.5.23
J6-00 - Outdoor unit: Malfunction of heat exchanger thermistor ............................................................... 32
3.5.24
L3-00 - Outdoor unit: Electrical box temperature rise problem................................................................... 32
3.5.25
3.5.26
L5-00 - Outdoor unit: Inverter instantaneous overcurrent .......................................................................... 33
3.5.27
P4-00 - Outdoor unit: Malfunction of radiating fin temperature sensor ..................................................... 35
3.5.28
U0-00 - Outdoor unit: Shortage of refrigerant ............................................................................................. 35
3.5.29
U2-00 - Outdoor unit: Defect of power supply voltage ................................................................................ 36
3.5.30
U4-00 - Indoor/outdoor unit communication problem................................................................................ 37
3.5.31
UA-00 - Indoor unit, outdoor unit mismatching problem ............................................................................ 38
3.5.32
UH-00 - Malfunction of system ..................................................................................................................... 38
3.6
Symptom based troubleshooting ................................................................................................................................... 40
3.6.1
Operation does not start................................................................................................................................ 40
3.6.2
Operation sometimes stops ........................................................................................................................... 40
3.6.3
Operation starts but the unit does not cool/heat ......................................................................................... 41
3.6.4
Operating noise and vibrations ...................................................................................................................... 43
3.6.5
Abnormal high pressure ................................................................................................................................. 44
3.6.6
Abnormal low pressure .................................................................................................................................. 45
3.6.7
Indoor fan starts operating but the compressor does not operate.............................................................. 47
3.6.8
Operation starts and the unit stops immediately.......................................................................................... 48
3.6.9
Operation stops, unit cannot start for a while .............................................................................................. 49
3.6.10
Indoor unit discharges white mist.................................................................................................................. 49
3.6.11
Humidifying problem...................................................................................................................................... 50
3.6.12
Swing flap does not operate .......................................................................................................................... 50
4.1
Electrical circuit............................................................................................................................................................... 51
4.1.1
Checking procedures ...................................................................................................................................... 51
RXM20~50A + ARXM25~50A + FTXM20~50A + ATXM20~50A + CTXM15A
6
6
7
7
14
15
51
Split Perfera ZETA R32
ESIE23-06 - 2023.12