Download Print this page

Mitsubishi Electric PUZ-WZ50VAA Service Manual page 44

Air to water heat pump units, outdoor unit, salt proof, r290
Hide thumbs Also See for PUZ-WZ50VAA:

Advertisement

Symptoms: "PLEASE WAIT" is kept being displayed on the remote controller.
Check the display time of "PLEASE WAIT"
after turning on the main power.
6 minutes
or more
Check the LED display of the
outdoor controller circuit board.
Are any check codes
displayed on the LED?
NO
OCH816
Diagnosis flow
2 minutes
or less
How long is "PLEASE WAIT"
kept being displayed on the
remote controller?
2 to 6
minutes
Are any check codes
displayed on the
remote controller?
YES
YES
Cause
• "PLEASE WAIT"
will be displayed
during the startup
diagnosis after turning
on the main power.
NO
• Miswiring of indoor/
outdoor connecting
wire
• Breaking of indoor/
outdoor connecting
wire (S3)
• Defective indoor
controller board
• Defective outdoor
controller circuit
board
• Defective indoor
controller board
• Defective remote
controller
44
Inspection method and
troubleshooting
• Normal.
The startup diagnosis will
be over in around 2 minutes.
• Refer to "9-2. SELF-
DIAGNOSIS ACTION
TABLE" in order to
solve the trouble.
• In case of communication
errors, the display of
remote controller may not
match the LED display of
the outdoor unit.

Advertisement

loading