(4) When installed in a location where only the front opened (building walls on both sides)
Where the distance between both sides of the unit and the wall is more than 1 m, define
the protective zone as follows: (Fig. 2-6)
- 1 m to the sides and to the front of the unit
- the rear of the unit to the wall
- 0.3 m from the ground.
0.3 m
1 m
1 m
1 m
Fig. 2-6
Where the distance between both sides of the unit and the wall is less than 1 m, define the
protective zone as follows: (Fig. 2-7)
- from the both sides of the unit to the wall
- 2.5 m to the front of the unit
- the rear of the unit to the wall
- 0.3 m from the ground.
0.3 m
< 1 m
< 1 m
2.5 m
Fig. 2-7
Where the distance between one side of the unit and the wall is less than 1 m, same
conditions as shown in Fig. 2-5 apply.