(8) Cover the system for safety
To use this product safely, be sure to cover the inverter board and the noise filter with an enclosure made of
metal or flame-retardant material with sufficient strength to prevent direct touch as shown in Fig. 3-10. The
enclosure should have slits for heat radiation and holes for cables to pass through.
In addition, regarding the disconnecting device (circuit protector), it should be properly located as follows.
- Do not locate it so that it is difficult to operate the device.
- It must be suitably located and easily reached.
- It must be marked as the disconnecting device for this product.
Provide sufficient ventilation
to prevent heat from building
up inside the case.
motor
PC

3.2 Power supply

There are two ways to supply main power to the inverter board.
When AC voltage is input as main power, sub power (DC15V) is generated internally. System configuration
is shown in Fig. 3-11.
When DC voltage is input as main power, sub power (DC15V) must be supplied externally. System
configuration is shown in Fig. 3-12.
USB5V power supply for communication I/F is needed for both cases.
When using the DC input, be sure to input a 15 V sub power supply before inputting the main power supply.
Also, when shutting off the power supply, be sure to turn off the 15V sub power supply after turning off the
main power supply. Inputting main DC power without a 15V sub power input may damage the board.
The inrush current limitation function does not work with this product when DC power is supplied. Therefore,
when using DC power supply, the current limit of about 10 to 30A should be applied on the power supply side,
or the power supply voltage should be turned on slowly over about 50 to 100ms.
Similarly, when DC voltage is turned off, it is recommended to disconnect the output or slowly lower the power
supply voltage to prevent large current from flowing into the power supply side.
Item
Main power (AC)
Main power (DC)
Sub power (DC15V) CN6
USB power
R12UZ0138EJ0100 Rev.1.00
February 28, 2024
Noise filter
Fig. 3-10 Setup for safe operation
Table 3-2 Power supply for this product
Connector
Use
CN2
Main power
CN3
Main power
Control circuit
Only needed for "Main power (DC)"
CN12
Communication I/F power
Cover the main unit with a
case, etc. to prevent direct
contact with the housing
Circuit
protector
Provide a hole in the case for passing cables
through to connect to external equipment
AC power
Voltage
AC100~240V
DC141~390V
DC15V
DC5V