9. Taking out of operation

The mains switch should not be turned to "OFF" during the burn-off but only after
complete burn-off. (Status: unit off)

10. Boiler operation

A. Heating up
After the casing door is opened the "burning" phase starts automatically.
If it is not desired or necessary to heat up the boiler, this process can be interrupted with
a long press of the On/Off button and confirmation of the SWITCH OFF message by
once again pressing On/Off.
To form a good flame it is recommended that the lower third of the filling shaft be filled
with small pieces of wood. After that normally chopped wood (size around 8cm) can be
used for filling.
Then open the lighting up door (4) and light up with an oil ignition, wood shavings or
cardboard. After this all doors should be closed once again.
1
2
3
4
5
6
7
8
9
Legend:
1...BioControl 3000
2...Filling shaft door
3...Primary air feed
4...Lighting-up door
5...Burner plate
6...Secondary air aperture
7...Ash doors
Betriebsanleitung firestar 15-40 English V2.8
10
8...Viewing glass
9...Ash tray
10...Secondary air aperture
11...Primary air aperture
12...Cleaning cover
13...Turbulators
14...Lambda sensor
11
12
13
16
15...Ventilator
16...Heat recovery area
17...Cleaning brush (optional)
18...Bellows for burner plate
19...Bellows for primary air feeds
14
15
17
18
19
Page 13 of 71