Deye SUN-10K-G05-LV User Manual page 32

Grid-connected pv inverter
Table of Contents

Advertisement

Name
Exp_Mode
CT_Ratio
MFR
Feedin
Shunt
ShuntQTY
Generator
G.CT
G.MFR
G.Cap
Note
:
Select Meter option in Run Param and long press ENTER button to enter this
Meter Setting page.
Description
AVG: Average power of three phase is zero exported.
MIN: Phase with minimum load power is zero
exported, while the other two phase may be
in purchase mode.
CT ratio of power grid side meter when extern CT is
applied.
Manufacturer of the grid side meter. Modbus
Address of it should be set as 01.
Percentage of the Feed in power exported to the
grid.
Parallel mode. Set one inverter as Master, others
are Slave. ONLY need to set the master, Slave will
follow the settings in the master.
Number of inverters in parallel
DG side meter function Enable/Disable
CT ratio of power DG side meter when extern CT is
applied.
Manufacturer of the DG side meter. Modbus
Address of it should be set as 02.
Capacity of the DG.
- 29 -
Range
AVG/MIN
1-1000
AUTO/CHNT/
EASTRON
0-110%
OFF/Master/
Slave
1-16
ON/OFF
1-1000
AUTO/CHNT/
EASTRON
1-999kW